Table 4
NOTES: *1 cable dimensioned for a length of 6m. Industrial voltage drop
Δ
V%
≤
1%
MODEL
TYPE OF
CONDENSING
UNIT
POWER CABLE
SECTION
*
1
POWER SUPPLY
Voltage (V)
Frequency (Hz)
Poles
Power (kW)
Current (A)
ABSORPTION
Air
Air
Air
220-240
200/208
400
230
200/208
400
230
200/208
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
1P+N+PE
2P+PE
3P+N+PE
3P+PE
3P+PE
3P+N+PE
3P+PE
3P+PE
1,3
1,3
2,7
3,0
3,0
4,1
4,6
4,6
6,2
6,8
4,4
8,9
8,7
7,0
12,9
12,8
4G2,5
3G12AWG
5G2,5
4G2,5
4G10AWG
5G2,5
4G6
4G10AWG
2.7. REFRIGERATION CONNECTION
2.7.1 R404a pressure switch calibration
2.8. CONDENSATION DRAIN
The blast chillers are equipped with a small tray to
gather condensation. The tray can put extracted from
the bottom part of the Blast chiller.
For calibration of the R404a pressure switches
see
Table 5
Table 5
MODEL
HIGH
PRESSURE
SAFETY
VALVE
(Bar)
(Bar)
ICY S
ICY M
ICY L
27
27
27
NA
30
30
2.9. INFORMATION FOR THE INSTALLER
•
•
•
Checking a correct installation and inspection:
Check the electrical connections.
Check the absorptions.
Check the standard pressures.
The safety devices must be installed in such a way that
leakage of refrigerant cannot cause any danger.
Inform the customer on the exact use of the
equipment, with specific reference to the use and
needs of the customer.
Installation and commissioning must be carri-
ed out by authorised personnel.
ICY S
ICY M
ICY L