![irinox ICY L Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/irinox/icy-l/icy-l_use-and-maintenance-instructions_2090427023.webp)
23
(+3 - DELICATE)
A= automatic cycle – M = manual cycle
S1
S3
A1
M1
STAGE_1 air set
Storage air Setting
STAGE_1 core temp. set
STAGE_1 time
1°C
1°C
1°C
1min
+1°C
+2°C
+3°C
90 min.
Blast chilling air
temperature
Cycle end core
temperature
Blast chilling
duration
Set
Description
Ris.
Default
Notes
-40 °C÷+40 °C
-40 °C÷+40 °C
-40 °C÷+40 °C
1 ÷ 180 min
Range
S1
S2
S3
A1
A2
M1
M2
STAGE_1 air set
STAGE_2 air set
Storage air Setting
STAGE_1 core temp. set
STAGE_2 core temp. set
STAGE_1 time
STAGE_2 time
1°C
1°C
1°C
1°C
1°C
1min
1min
-20°C
-1°C
+2°C
+20°C
+3°C
30min.
60min.
First stage blast
chilling air temperature
Cycle end blast
chilling air temperature
First stage end
core temperature
Cycle end core
temperature
Stage 1 blast
chilling duration
Stage 2 blast
chilling duration
Set
Description
Ris.
Default
Notes
-40 °C÷+40 °C
-40 °C÷+40 °C
-40 °C÷+40 °C
-40 °C÷+40 °C
-40 °C÷+40 °C
1÷ 180 min.
1÷ 180 min.
Range
Description
Function
The list of parameters that can be modified appears
after accessing the user parameters page.
Press and to switch to the next/previous
parameters.
To save the modified parameter, press
Press the key to go back to the previous screen;
if
is not pressed after modifying a parameter,
and you go back, the modification is cancelled.
The key can be used to go back to the first
parameter, without exiting the cycle parameters page.
Likewise can be used to reach the last parameter
2A
Front panel screen
USER PARAMETERS
CYCLE PARAMETERS
(+3 - STRONG)
A= automatic cycle – M = manual cycle
Содержание ICY L
Страница 35: ......