16
Description
Phase
Front panel screen
11A
12A
5B
6B
7B
8B
9B
10A
Press the info symbol
to display the air temperature, core temperature
and the cycle duration time for 3 seconds.
AUTOMATIC MODE
Insert the Core probe into the product
Close the Blast Chiller door
Press the “Automatic” cycle key to put the
selected cycle in automatic mode.
Press the
key to start the selected cycle.
At the end of the cycles a sound is emitted and the
system switches to preservation mode, displaying the
time elapsed since the beginning of the cycle.
Press to go back to the initial grid.
Press to put the screen in stand-by while the cycle
is active.
Do not use the Blast Chiller as a Holding Cabinet.
Open the Blast Chiller door, extract the trays with
the blast chilled food and place them in the Holding
Cabinet.
Once the cycle has started:
Press to put the system in stand-by.
Use
the key to stop the cycle and
go back to the initial grid.
Press the symbol to display the air temperature,
core temperature and the cycle duration time for 3
seconds.
This function can be used to determine, when the
cycle has concluded, the time necessary for blast
chilling a typical product.
This time can be used successively to blast chill a
similar product using the MANUAL mode
Содержание ICY L