2.12.  R404A GAS SAFETY SHEET

• Identification of dangers

High exposure to inhalation can have anaesthetic 
effects. Very high exposure can cause anomalies of the 
heart beat and cause sudden death. The neubulised or 
sprayed product can cause cold burns to the eyes or 
skin. Dangerous for the ozone layer.

• First aid measures

Inhalation

Move the accident victim away from exposure and keep 
him/her warm and rested. Give oxygen if necessary.
Perform artificial respiration if breathing stops or gives 
signs of stopping. In the case of cardiac arrest, perform 
external cardiac compression.
Request immediate medical assistance.

Contact with the skin

Thaw the affected areas using water.
Remove contaminated clothing.
Attention: clothing can stick to the skin in the case of 
cold burns. In the case of contact with the skin, wash 
immediately with plenty of warm water. If symptoms 
occur (irritation or the formation of blisters) request 
medical assistance.

Contact with the eyes

Wash immediately with an eyewash or clean water, 
keeping the eyelids open for at least 10 minutes. 
Request immediate medical assistance.

Ingestion

Do not induce vomiting.
If the accident victim is conscious, rinse the mouth with 
water and make him/her drink 200-300 ml of water.
Request immediate medical assistance.

Further medical care

Symptomatic treatment and support therapy when 
indicated. Do not give adrenalin and similar 
sympathomimetic drugs following exposure, due to the 
risk of cardiac arrhythmia with possible cardiac arrest.

• Fire-prevention measures

Not inflammable.
The heat decomposition causes the emission of very 
toxic and corrosive vapours (hydrogen chloride, 
hydrogen fluoride). In the case of fire, use respiratory 
aids and suitable protective clothing.

Extinguishers

Use extinguishing agents that are appropriate for the 
fire.

• Use extinguishing agents that are appropriate for 
the fire.

Inhalation

Higher atmospheric concentrations can cause anaesthetic 
effects with possible loss of consciousness.
Very high exposure can cause anomalies of the heart 
beat and cause sudden death.
Higher concentrations can cause asphyxia due to the 
reduced content of oxygen in the atmosphere.

Contact with the skin

Sprays of liquid and the nebulised liquid can cause 
cold burns.
It is improbable that it is dangerous due to cutaneous 
absorption.
Repeated and prolonged contact can cause the removal 
of sebaceous matter, with consequent dryness, cracking 
and dermatitis.

• Ecological information

It decomposes relatively quickly in the lower atmosphere 
(troposphere). The decomposition products are highly 
dispersed and therefore have a very low concentration.
Does not affect photochemical smog (i.e. it does not lie 
within the volatile organic compounds -VOC- according to 
that established by the UN/ECE agreement).
T h e  o z o n e  d e s t r u c t i o n  p o t e n t i a l  ( O D P )  i s  0 . 0 5 5 
measure in comparison with a standard ODP equal to 
1 for the cfc11 (according to uNeP definitions). The 
Global Warming Potential of the gas is 3260.
The substance is governed by the Montreal Protocol 
(revision dated 1992).
The discharges of the product into the atmosphere do 
not cause contamination of waters in the long term.

• Considerations regarding disposal

The best solution consists in recovery and recycling of 
the product.
If this is not possible, destruction must take place in an 
authorised plant equipped to absorb and neutralise the 
acid gases and the other toxic products.

• Measures in the case of accidental leaks

Ensure adequate personal protection (with the use of 
means of protection for the respiratory tract) during the 
elimination of spills.
If the conditions are sufficiently safe, isolate the source 
of the leak. In the presence of spills of modest size, 
leave the material to evaporate on the condition that 
there is suitable ventilation.
Large leaks
-ventilate the area;
-contain the leaking material with sand, earth or other 
suitable absorbent material; 
-prevent the liquid from penetrating drains, sewers, 
basements and work holes, because the vapours can 
create a suffocating atmosphere.

• Handling

Avoid the inhalation of high concentrations of vapours.
The atmospheric concentrations must be reduced to a 
minimum and kept at the minimum level reasonably 
possible, below the professional exposure limit.
The vapours are heavier than the air and therefore the 
formation of high concentrations near to the ground is 
possible, where ventilation is usually low. In these cases, 
ensure adequate ventilation or wear suitable protection 
devices for the respiratory tract with air reserve. Avoid 
contact with naked flames and hot surfaces as irritant and 
toxic decomposition products can be formed. Avoid 
contact between the liquid and the eyes/skin.

Содержание ICY L

Страница 1: ...N REV REVISION DESCRIPTION DATE REV REVISER 00 FIRST EMISSION 01 12 2015 NC U S E A N D M A I N T E N A N C E I N S T R U C T I O N S...

Страница 2: ...ne easy and intuitive to use Symbols key suggestions and details for correct use of the blast chiller standards for your safety additional information in this manual Information regarding the warranty...

Страница 3: ...the power supply having a contact separation of all poles that pro vide disconnection in category III overvoltage conditions must be equipped with a disconnec tion device incorporated in the fixed con...

Страница 4: ...RATION POWER 9 2 6 ELECTRICAL CONNECTION 9 2 7 REFRIGERATOR CONNECTION 10 2 8 CONDENSATION DRAIN 10 2 9 SAFETY AND CONTROL SYSTEMS 10 2 10 SAFETY AND CONTROL SYSTEMS 11 2 11 DISPOSAL OF THE MACHINE 11...

Страница 5: ...n compliance with directive 97 23 EC based on the model the equipment is supplied together with the user manuals and declarations of conformity of the safety valve liquid receiver liquid separator liq...

Страница 6: ...op Extract the core probe s from the product and posi tion it them on the probe holder Use suitable gloves for cold trays and trolleys 1 7 DANGEROUS USE OF THE SHARP PROBE Use of the probe is allowed...

Страница 7: ...ent prevention Law Standards with traditional rules and with Standards now in force The installer must check potential fire prevention prescriptions contact the nearest fire station for the due indica...

Страница 8: ...474mm DRAIN PIPE 20mm DRAIN PIPE 20mm 400mm 383 mm 1475mm ICY S ICY M ICY L 383 mm 474mm AIR FLOW AIR FLOW Min 75 mm 774mm 884mm 89mm 187mm 68mm 68mm 1453mm min 70 mm min 30 mm 115mm 165mm 765mm 400mm...

Страница 9: ...ion cables must comply with the information contained in the electric data of the technical files The voltage of the plants must be within the limit of 10 and voltage unbalance of the phases must not...

Страница 10: ...ON DRAIN The blast chillers are equipped with a small tray to gather condensation The tray can put extracted from the bottom part of the Blast chiller For calibration of the R404a pressure switches se...

Страница 11: ...e 2011 65 CE 2012 19 UE and 2003 108 CE Directives relative to the reduction of use of dangerous substances in electric and electronic appliances as well as disposal of waste The barred bin symbol on...

Страница 12: ...ld burns It is improbable that it is dangerous due to cutaneous absorption Repeated and prolonged contact can cause the removal of sebaceous matter with consequent dryness cracking and dermatitis Ecol...

Страница 13: ...empera ture of 0 C In the second phase the core temperature of the product is brought to 18 C with an operation temperature that can reach 40 C This cycle is particularly indicated for shock freezing...

Страница 14: ...will have time to heat the compressor This avoids breakdown at the first turn on due to returning refrigerant liquid 1 Start the chosen cycle for at least 5 minutes before putting the hot food into t...

Страница 15: ...lity to increase or decrease the cycle time by pressing the plus and minus keys Press and hold for over two seconds to increase the time faster Press the key to start the selected cycle The timer cann...

Страница 16: ...the cycle Press to go back to the initial grid Press to put the screen in stand by while the cycle is active Do not use the Blast Chiller as a Holding Cabinet Open the Blast Chiller door extract the...

Страница 17: ...Press on the home screen to access the defrost mode Defrost cycle selection and start up Description Function 1 Use the keys shown on the display to change the time Press the key to start the selecte...

Страница 18: ...e print log 4 When the download is complete the display shows Completed If the download fails or the USB pen drive is not connected the display shows Error If you press the button during the download...

Страница 19: ...containers with a product weighing 3 5 kg and with a maximum thickness of 8 cm for blast chilling or 5 cm for shock freezing For difficult products and or fats reduce thickness even more Make sure to...

Страница 20: ...nation For better results load the GN1 1 containers with a product weighing 3 5 kg and with a maximum thickness of 8 cm for blast chilling or 5 cm for shock freezing For difficult products and or fats...

Страница 21: ...s for the cycles start at 90 C from 90 C to 3 C or the blast chilling cycle from 90 C to 18 C for the shock freezing cycle 3 6 6 Preservation Blast chilled and or shock frozen food must be properly co...

Страница 22: ...ed for the DELICATE 3 C cycle for the STRONG 3 C cycle for the DELICATE 18 C cycle for the STRONG 18 C cycle for the defrosting cycle The list of parameters that can be modified appears after selectin...

Страница 23: ...First stage end core temperature Cycle end core temperature Stage 1 blast chilling duration Stage 2 blast chilling duration Set Description Ris Default Notes 40 C 40 C 40 C 40 C 40 C 40 C 40 C 40 C 40...

Страница 24: ..._2 time 1 C 1 C 1 C 1 C 1 C 1min 1min 0 C 35 C 19 C 6 C 18 C 60 min 180 min First stage freezing air temperature Cycle end freezing air temperature First stage end core temperature Cycle end core temp...

Страница 25: ...Selection setting Recording frequency setting expressed in minutes Recording mode selection Machine number setting Print language selection Software release display 3 digits Key tone enabling Sanitisi...

Страница 26: ...ll in the atmosphere which is the vehicle of 97 of bacterial contaminations for food Absence of bacteria allows to obtain the following advan tages inside the chamber continuous sanitising of the insi...

Страница 27: ...plastic base 5 Clean the glass cylinder with a damp cloth Remove any dust deposits carefully 6 8 Insert the external net paying attention not to overlap the internal net and keep a distance of about...

Страница 28: ...er clockwise with the external net always acting on the red plastic base 1 Release the external tab holding the glass cylinder still 3 Dispose of the glass cylinder with the external net as dry waste...

Страница 29: ...cleaning or routine maintenance disconnect the machine from the power supply network turning off the master switch and pulling the plug do not pull the power cord to disconnect the machine from the po...

Страница 30: ...r to loosen the screw located at the right side of the fan holding panel and turn it to the left Do not use sharp objects METHODS FOR CLEANING EVAPORATOR In order to clean the evaporator a brush can b...

Страница 31: ...ped grid with force For remote condensing units the air condenser must be kept clean to allow free air flow This operation which must be carried out at least every 30 days can be done with non metalli...

Страница 32: ...oken Technician intervention Replace S1 probe Replace S2 probe Probes S1 and S2 are broken Possible cause Possible solution Description Phase Front panel screen RESETTING THE ALARM RECORDING MEMORY 1...

Страница 33: ...an to replace device Fan broken Intervention of a technician to replace fan Start condenser broken Intervention of a technician to replace start condenser Compressor remote switch consent missing Inte...

Страница 34: ...condensing plant where applicable Remove the rear protection grid by undoing the screws with a flat head screwdriver Fig 14 4 5 EXTRAORDINARY MAINTENANCE 4 5 1 How to access the front circuit board T...

Страница 35: ......