Adding more rules is done by setting the parameter number of SMS sending rules to
desired value.
8.2.7.3.1. Number of CLIP calls rules
Function
- declares number of CLIP calls rules
Data type
- number
Range
- 1....32
Default
value
- 1
Comments
- diminishing the number of rules does not delete settings until
the configuration is written to the module.
8.2.7.3.2. Number of trials
Function
- defines number of consecutive retries if the called number is
busy or unavailable
Data type
- number
Range
- 0....255
Default
value
- 3
Comments
-
0
(
zero
) value results with no redial attempts.
8.2.7.3.3. Interval between trials
Function
- defines (in seconds) interval between consecutive redial
attempts
Data type
- number
Range
- 0....255 [s]
Default
value
- 20 [s]
Comments
-
0
(
zero
) value results in an immediate redial