154
0x407 1031 41032 MC1HH1_L
32 bit (H..L) floating point
0x408 1032 41033 MC1LL2_H
LL threshold for VAR1 of counter 1
32 bit (H..L) floating point
0x409 1033 41034 MC1LL2_L
… … … …
…
0x40E 1038 41039 MC1HH2_H
HH threshold for VAR2 of counter 1
32 bit (H..L) floating point
0x40F 1039 41040 MC1HH2_L
0x410 1040 41041 MC1LL3_H
LL threshold for VAR3 of counter 1
32 bit (H..L) floating point
0x411 1041 41042 MC1LL3_L
… … … …
…
0x43E 1086 41087 MC1HH8_H
HH threshold for VAR8 of counter 1
32 bit (H..L) floating point
0x43F 1087 41088 MC1HH8_L
0x440 1088 41089 MC2LL1_H
LL threshold for VAR1 of counter 2
32 bit (H..L) floating point
0x441 1089 41090 MC2LL1_L
… … … …
…
0x47E 1150 41151 MC2HH8_H
HH threshold for VAR8 of counter 2
32 bit (H..L) floating point
0x47F 1151 41152 MC2HH8_L
0x480 1152 41153 MC3LL1_H
LL threshold for VAR2 of counter 3
32 bit (H..L) floating point
0x481 1153 41154 MC3LL1_L
… … … …
…
0x7FE 2046 42047 MC16HH8_H
HH threshold for VAR8 of counter 16
32 bit (H..L) floating point
0x7FF 2047 42048 MC16HH8_L
Binary outputs space
Alarm bits informing on comparison results with current values of gas counters.
Start Address
Name
Description
hex dec MODBUS
0x0B8 184
10185
MC1V1LL
LL alarm bit for VAR1, counter 1
0x0B9 185
10186
MC1V1L
L alarm bit for VAR1, counter 1
0x0BA 186
10187
MC1V1H
H alarm bit for VAR1, counter 1
0x0BB 187
10188
MC1V1HH
HH alarm bit for VAR1, counter 1
0x0BC 188
10189
MC1V2LL
LL alarm bit for VAR2, counter 1
0x0BD 189
10190
MC1V2L
L alarm bit for VAR2, counter 1
0x0BE 190 10191
MC1V2H
H alarm bit for VAR2, counter 1
0x0BF 191 10192
MC1V2HH
HH alarm bit for VAR2, counter 1
0x0C0 192
10193
MC1V3LL
LL alarm bit for VAR3, counter 1
… … …
…
…
0x0D7 215
10216
MC1V8HH
HH alarm bit for VAR8, counter 1
0x0D8 216
10217
MC2V1LL
LL alarm bit for VAR1, counter 2
… … …
…
…
0x0F7 247 10248
MC2V8HH
HH alarm bit for VAR8, counter 2
0x0F8 248 10249
MC3V1LL
LL alarm bit for VAR1, counter 2
… … …
…
…
0x2B7 695
10696
MC16V8HH
HH alarm bit for VAR8, counter 16
Bits informing on state of communication with gas meter
Start Address
Name
Description
hex dec MODBUS
0A8 168 10169 SL1_ok
1 – proper communication with counter 1
0A9 169 10170 SL2_ok
1 – proper communication with counter 2
0AA 170 10171 SL3_ok
1 – proper communication with counter 3
0AB 171 10172 SL4_ok
1 – proper communication with counter 4
0AC 172 10173 SL5_ok
1 – proper communication with counter 5
0AD 173 10174 SL6_ok
1 – proper communication with counter 6
0AE 174 10175 SL7_ok
1 – proper communication with counter 7
Содержание MT-101