146
Address + 0
+ 1
+ 2
+ 3
+ 4
+ 5
+ 6
+ 7
Description
Virtual
registers
0x0000
Q1
Q2 Q3 Q4
Q5 Q6 Q7m
Q8
bits controlling outputs Q1..Q8
(forcings)
0x0008
P1
P2 P3 P4
P5 P6 P7
P8
Program flags enabling rule based
data transmission on event.
0x0010
P9 P10 P11 P12
P13 P14 P15
P16
VREG_BO1
0x0018
CLK_C1
CLK_C2 CLK_C3 CLK_C4
CLK_C5 CLK_C6 CLK_C7
CLK_C8
Counting inputs C1..C8 (raising
edge)
0x0020 RST_C1
RST_C2 RST_C3 RST_C4
RST_C5 RST_C6 RST_C7
RST_C8
Counter resetting inputs C1..C8
(active state 1)
VREG_BO2
0x0028
EN_T1
EN_T2 EN_T3 EN_T4
EN_T5 EN_T6 EN_T7
EN_T8
Strobe inputs for timers T1..T8
(active state 1)
0x0030
RST_T1
RST_T2 RST_T3 RST_T4
RST_T5 RST_T6 RST_T7
RST_T8
Reset inputs for timers T1..T8
(active state 1)
VREG_BO3
0x0038 PS1_stop MLOG_act
GPRS_data MLOG_rd P2RCV_err P2SND_err x
x
PS1_stop
= 1 - Program stop
MLOG_act
= 1 - activate
MiniLogger
GPRS_data
- bit set at every
reception of a data frame via GPRS
MLOG_rd
= 1 - force MiniLogger
readout, reset after readout
P2RCV_err
= 1 - byte reception
error (f.e. transmission parameter
or buffer overflow), reset by user
program.
P2SND_err
= 1 - buffer
transmission error (f.e. wrong
size), reset by user program.
0x0040
P17
P18 P19 P20
P21 P22 P23
P24
Program flags enabling rule based
data transmission on event.
VREG_BO4
0x0048
P25
P26 P27 P28
P29 P30 P31
P32
0x0050
BU80
BU81 BU82 BU83
BU84 BU85 BU86
BU87
General purpose user fags
VREG_BO5
0x0058
BU88
BU89 BU90 BU91
BU92 BU93 BU94
BU95
General purpose user fags
…
General purpose user fags
0x00F0
BU240
BU241 BU242 BU243
BU244 BU245 BU246
BU247
General purpose user fags
VREG_BO15
0x00F8
BU248
BU249 BU250 BU251
BU252 BU253 BU254
BU255
General purpose user fags