22
5.5. Power supply
The power supply is connected to „+” and „-” terminals (preserving polarisation only when
supplying direct current).
Pin
Description
GND
Module's ground *
UPS
Input – power supply state signaling. Active state for voltage >
10,8V
When not employed , shortcut with +.
+
Positive pole of power supply**
-
Negative pole of power supply**
*
- Not recommended in standard appliances since it may increase emitted noise.
**
- For AC supply polarisation does not apply.
Example:
Connection diagram with battery backup
NOTICE!
Due to MT-101 module's high momentary current consumption the supply
must be capable of delivering >= 2A current.
Improper power supply may result in faulty operation and damage the
module!