3. Enter the admin password and click OK.
4. Click
OK
in the pop-up message box to confirm restoring operation.
Import/export a configuration file
The administrator can export and import configuration settings from the camera. This is
useful if you want to copy the configuration settings to another camera, or if you want to
make a backup of the settings.
Note
: Only the administrator can import/export configuration files.
To import/export configuration file:
1. From the Configuration panel, click
Configuration
>
Security
>
Maintenance
.
2. Click
Browse
to select the local configuration file and then click
Import
to start
importing configuration file.
3. Click
Export
and set the saving path to save the configuration file.
Upgrade firmware
The camera firmware is stored in the flash memory. Use the upgrade function to write
the firmware file into the flash memory.
You need to upgrade firmware when it has become outdated. When you upgrade the
firmware, all existing settings are unchanged. Only the new features are added with
their default settings.
The camera will select the corresponding firmware file automatically. Cookies and data
in the web browser are automatically deleted when the firmware is updated.
To upgrade the firmware version:
1. Download on to your computer the latest firmware from our web site.
2. When the firmware file is downloaded to your computer, extract the file to the
desired destination.
Note
: Do not save the file on your desktop.
3. From the Configuration panel, click
Configuration
>
Security
>
Maintenance
.
Select the
Firmware
or
Firmware Directory
option. Then click the Browse button to
locate latest firmware file on your computer.
•
Firmware directory
– Locate the upgrading folder of Firmware files. The camera
will choose the corresponding firmware file automatically.
•
Firmware
– Locate the firmware file manually for the camera.
Note
: Please select Interlogix_Gen_3_ipc.dav for camera models listed in the
“Introduction” on page 3.
4. Click
Update
. You will receive a prompt asking you to reboot the camera.
5. When the upgrade is finished, the device will reboot automatically. The browser will
also be refreshed.