![Interlogix TruVision TVB-5701 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/interlogix/truvision-tvb-5701/truvision-tvb-5701_configuration-manual_2077161061.webp)
TruVision IP Thermal Camera Configuration Manual
59
arms so that they are now larger than the maximum size), an alarm will not
be triggered.
g) Draw the line/area on the live video image.
For cross line detection, draw a line and select the crossing direction, which is
bidirectional, A-to-B, or B-to-A.
For other events such as intrusion, region entrance, and region exiting, left-click
the live video image to set the end points of the area and right-click to finish the
area drawing. Click
Draw Area
/
Draw Line
again to delete the drawn area/line.
Note
: If live view stops, you cannot draw the detection area/line nor set any
rules.
h) Click
Save
to save the settings.
5. Set the arming schedule.
Click the
Arming Schedule
tab. Click
Edit
to set the schedule time for each alarm
rule. Click
Save
to save the settings.
6. Set the alarm linkage.
Click the
Alarm Linkage
tab. Select the check box of the desired linkage methods
for each rule. Click
Save
to save the settings. See page 34 for further information on
linkage methods.
7. Set the VCA parameters.
From the Configuration panel, click
VCA Configuration
>
Advanced
Configuration
>
Parameters
.
Enter the desired parameters:
Parameter
Description
1. Detection Sensitivity [0~4]
This is the camera’s sensitivity to detect a target. The higher the
value, the easier a target is to recognize and the higher the
misinformation. Default value is 3.
2. Background Update Rate
[0~4]
This is the speed at which a new scene replaces the previous
scene. Default value is 2.