Send Email
Sends an email to a specified address when there is an alarm
triggered.
Note:
You must configure email settings before enabling this option.
See “To set up the email parameters” on page 18 for further
information. If you want to send the event snapshot together with the
email, select the Attached Snapshot option.
Trigger Alarm Output
Trigger external alarm outputs when an event occurs. Select “Select
All” or individual alarm outputs.
Note:
This option is only supported by cameras that support alarm
output.
6. Click
Save
to save changes.
Alarm inputs and outputs
To define the external alarm input:
1. From the Configuration panel, click
Configuration
>
Basic
Event
>
Alarm Input
.
2. Choose the
Alarm Input No.
and the
Alarm Type
. The alarm type can be NO
(Normally Open) or NC (Normally Closed). Enter a name for the alarm input, if
desired.
3. Click
Edit
to set the arming schedule for the alarm input. The arming schedule
configuration is the same as that for motion detection. See “Set the arming
schedule” on page 36 for more information.
4. Specify the linkage method. Select one or more response methods for the system
when an alarm input is triggered.
Notify Surveillance Center
Send an exception or alarm signal to remote management software
when an event occurs.
Send Email
Sends an email to a specified address when there is an alarm input
or output alarm.
Note:
You must configure email settings before enabling this option.
See “To set up the email parameters” on page 18 for further
information. If you want to send the event snapshot together with the
email, select the Attached Snapshot option.
Trigger Alarm Output
Trigger external alarm outputs when an event occurs. Select “Select
All” or individual alarm outputs.
Note:
This option is only supported by cameras that support alarm
output.
5. Click
Save
to save changes.
To define alarm output:
1. From the Configuration panel, click
Configuration
>
Basic
Event
>
Alarm Output
.
2. Select one alarm output channel from the
Alarm Output
drop-down list. You can
also set a name for the alarm output.
3. The delay time can be set to 5 s, 10 s, 30 s, 1 min, 2 min, 5 min, or 10 min. The
delay time refers to the time duration that the alarm output remains in effect after the
alarm occurs.