TruVision IP Thermal Camera Configuration Manual
4. Set the alarm rules for the point/line/frame just created.
Point rule:
a) Click
to display the “Alarm Rule” setup window.
b) From the drop-down list, select one of the “Alarm Rule” options: Average
Temperature is Higher than, or Average Temperature is Lower than.
For example, select “Alarm Rule” as
Average Temperature is Higher than
, and
set the “Alarm Temperature” to 50 °C (122 F°). The device triggers an alarm
when its average temperature is higher than 50 °C.
c) Enter the temperature values of the
Alarm Pre-Alarm Temperature
,
Alarm
Temperature
, and
Tolerance Temperature
.
For “Tolerance Temperature”, the triggered alarm stops when the device
temperature/temperature difference is less than the rule temperature by the set
tolerance temperature. For example, set the tolerance temperature to 3 °C
(37.4 °F), set alarm temperature to 55 °C (131 °F), and set pre-alarm
temperature to 50 °C (122 F°). The device sends a pre-alarm when its
temperature reaches 50 °C (122 °F) and it triggers an alarm when its
temperature reaches 55 °C (131 °F). Only when the device temperature is lower
than 52 °C will the alarm be cancelled.
d) Click
OK
to save the changes.
Line rule:
a) Click
to show the
Alarm Rule
setup window.
b) Set the alarm rule. Select one of the six options:
Max. temperature is higher than, Max. temperature is lower than, Min.
temperature is higher than, Min. temperature is lower than, Average temperature
is higher than, or Average temperature is lower than.
c) Enter the values of the Alarm Pre-Alarm Temperature, Alarm Temperature, and
Tolerance Temperature.