4. Click
Edit
to set the arming schedule. The arming schedule configuration is the
same as that for motion detection. See “Set the arming schedule” on page 36 for
more information.
5. If required, select another day of the week to set a different schedule for alarm
outputs, or copy the same schedule to other days of the week.
6. Click
Save
to save changes.
Exception alarms
You can set up the camera to notify you when unexpected events occur and how you
should be notified. These exception alarms include:
• HDD Full:
All recording space on the NAS is full.
• HDD Error:
Errors occurred while files were being written to the storage, no storage
or storage had failed to initialize.
• Network Disconnected:
Disconnected network cable.
• IP Address Conflicted:
Conflict in IP address setting.
• Illegal Login:
Wrong user ID or password used to login to the cameras.
To define exception alarms:
1. From the Configuration panel, click
Configuration
>
Basic
Event
>
Exception
.
2. Under
Exception Type
, select an exception type from the drop-down list.
3. Specify the linkage method for when an event occurs. Select one or more response
methods for the system when an exception alarm is triggered.
Notify Surveillance Center
Send an exception or alarm signal to remote management software
when an event occurs.
Send Email
Sends an email to a specified address when there is an exception
alarm.
Note
: You must configure email settings before enabling this option.
See “To set up the email parameters” on page 18 for further
information. If you want to send the event snapshot together with the
email, select the Attached Snapshot option.
Trigger Alarm Output
Trigger external alarm outputs when an event occurs. Check “Select
All” or individual alarm outputs.
Note
: This option is only supported by cameras that support alarm
output.
4. Click
Save