TruVision IP Thermal Camera Configuration Manual
49
Click the Line icon and then left- click where you want the line to start and end on the
image. Right-click to finish drawing the area.
Click the Frame icon and then left- click where you want the line to start and end on the
image. Right-click to finish drawing the area.
Delete all points, lines, and frames on the image.
Note
: You can draw up to a total of 10 points, 1 line, and 10 frames.
3. Set the temperature measurement rules for the point/line/frame just created.
Select the check box of the first rule and enter the following information about this
rule. You can set up to up to 21 rules (10 points, 1 line, and 10 frames).
Name
: Enter the desired name for the rule.
Type
: Select Point, Line, or Frame as the rule type.
Point
: This is the temperature of the point you inserted in the live view image.
Line
: This is the temperature of the line you drew in the live view image.
Frame
: This is the temperature of the area you drew in the live view image.
Emissivity
: Set the emissivity (ability to emit infrared energy) of your target.
Values range from 0 (completely reflective target) to 1 (object emitting no
infrared energy).
Distance (m)
: Enter the straight-line distance between the target and the
device.
Reflective Temperature
: If there are any targets with high emissivity in the
scene, select the check box and set the reflective temperature to correct the
temperature. Default is unchecked.