Service replaceable units
67
6.
Remove the eight screws that secure the heat sink retention bracket to the system board, and put
the screws and the module in a safe place.
Notes:
a.
Note the alignment of the heat sink retention bracket (the arrow on the bracket aligns with
the arrow on the system board). You will need to align the bracket the same way when
reinstalling it.
b.
One of the screws also helps secure the system board to the blade chassis.
7.
Remove the other seven screws that secure the system board to the blade chassis, and put the
screws in a safe place.
8.
Pull the system board carefully out of the blade chassis.
Reverse these steps to install the replacement system board.
✏
NOTE
Two self-adhesive labels ship with the system board. Apply one on top of the existing ethernet
MAC address label located on the bottom of the blade chassis. The other label remains with
the owner.
Содержание SBXL52 - Server Compute Blade
Страница 10: ...x SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 14: ...xiv SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 24: ...10 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 32: ...18 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 76: ...62 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 82: ...68 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 116: ...102 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 120: ...106 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 122: ...108 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...