Symptom-to-FRU index
83
IDE RAID
Error symptoms
You can use the error symptom table to find solutions to problems that have definite symptoms.
If you cannot find the problem in the error symptom charts, go to “Starting the diagnostic programs”
on page 22 to test the server.
If you have just added new software or a new option and your server is not working, do the following
before using the error symptom charts:
•
Remove the software or device that you just added.
•
Run the diagnostic tests to determine if your server is running correctly.
✏
NOTE
See “System” on page 104 to determine which components should be replaced by a field service
technician.
Error symptom
FRU/action
Drives are not detected
1.
Verify that drives are installed correctly:
a.
Cables should be of type Ultra ATA-100 or ATA-133 and should be installed
correctly.
b.
Power cables to drives should be connected properly.
2.
Cables.
3.
Drive.
System hangs when
MegaRAID IDEal Software
CSB6 RAID adapter ROM
scans the IDE channels
1.
Verify that drives are installed correctly:
a.
Cables should be of type Ultra ATA-100 or ATA-133 and should be installed
correctly.
b.
Power cables to drives should be connected properly.
2.
Cables.
3.
Drive.
BIOS reports that a mirrored
array is in degraded mode
1.
Verify that all physical drives are:
a.
Installed correctly
b.
Powered on
2.
Reconnect, replace, or rebuild any failed drive.
One of the hard disk drives in
a mirrored array has failed
1.
Verify that drives are installed correctly.
2.
Replace drive with another drive of the same capacity.
"NO ROM BASIC SYSTEM
HALTED" message displays
during startup (There are no
active partitions)
1.
Verify that drives are installed correctly.
2.
Run FDISK to set active partition.
Operating system does not
boot
1.
Check system BIOS configuration for PCI interrupt assignments and
verify that some interrupts are assigned for PCI.
2.
Verify that the boot device in system BIOS setup (CMOS setup) is selected
correctly.
Содержание SBXL52 - Server Compute Blade
Страница 10: ...x SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 14: ...xiv SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 24: ...10 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 32: ...18 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 76: ...62 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 82: ...68 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 116: ...102 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 120: ...106 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...
Страница 122: ...108 SBXL52 Hardware Maintenance Manual and Troubleshooting Guide This page intentionally left blank ...