Figure 3-14 Terminal dimensions of MD290T315G to MD290T450G and MD290T400P to
MD290500P (without side entry copper bar, without output reactor)
2- 17
62
30
49
50
85
244
R
S
T
W
V
U
55
210
45
45
133
36
36
14-M16
340
Table 3-9 Recommended cable dimensions and tightening torque of MD290T315G(-L) to
MD290T450G(-L) and MD290400P(-L) to MD290500P(-L)
AC Drive Model
Rated Input
Current (A)
Power Input/
Output Cable
Crimp
Terminal
Model
Ground
Cable
Crimp
Terminal
Model
Tightening
Torque
(N·m)
Screw
Spec.
MD290T315G(-L)
565
2 x (3 x 185) mm
2
500 kcmil x 2P
250-16
185 mm
2
2/0 AWG
70-16
85.0
M16
MD290T400P(-L)
708
2 x (3 x 240) mm
2
600 kcmil x 2P
325-16
240 mm
2
3/0 AWG
80-16
85.0
M16
MD290T355G(-L)
617
2 x (3 x 185) mm
2
500 kcmil x 2P
250-16
185 mm
2
2/0 AWG
70-16
85.0
M16
MD290T450P(-L)
782
2 x (3 x 240) mm
2
600 kcmil x 2P
325-16
240 mm
2
3/0 AWG
80-16
85.0
M16
MD290T400G(-L)
687
2 x (3 x 240) mm
2
600 kcmil x 2P
325-16
240 mm
2
3/0 AWG
80-16
85.0
M16
MD290T500P(-L)
840
2 x (3 x 300) mm
2
650 kcmil x 2P
325-16
300 mm
2
80-16
85.0
M16
MD290T450G(-L)
782
2 x (3 x 240) mm
2
600 kcmil x 2P
325-16
240 mm
2
3/0 AWG
80-16
85.0
M16
Содержание MD290 Series
Страница 1: ......
Страница 79: ...3 Electrical Installation 78 3 ...
Страница 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Страница 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Страница 227: ...7 Interfaces and Communication 226 7 ...
Страница 285: ...10 Troubleshooting 284 11 ...
Страница 349: ......
Страница 350: ......