1. Product Information
- 15 -
1
Table 1-3 Ratings of MD290T200G to MD290T280G and MD290T220P to MD290T315P
Voltage Class
380 to 480 VAC
Model: MD290Txxxx(-L)**(-INT)
200G
220P
220G
250P
250G
280P
280G
315P
Drive Input
Rated Input Voltage
Three-phase 380 to 480V, -15% to +10%
Rated Input Current, [A]
365
410
410
456
441
507
495
559
Power Capacity, [kVA]
334
375
375
417
404
464
453
511
Rated input frequency
50/60 Hz, ±5%
Drive Output
Applicable Motor, [kW]
200
220
220
250
250
280
280
315
Output Current, [A]
377
426
426
465
465
520
520
585
Default carrier frequency, [kHz]
3
3
3
3
3
3
3
3
Overload Capacity
G type: 150% for 60 Sec
P type: 110% for 60 Sec
Max. output voltage
Three-phase 380 to 480 VAC (proportional to input voltage)
Max. output frequency
500 Hz
Braking
Resistor
Recommended Power, [kW]
38
38
42
42
48
48
54
54
Recommended Resistance,
PLQ>@
2.9
2.9
2.7
2.7
2.3
2.3
2.1
2.1
Thermal
Design
Thermal design power, [kW]
4.15
4.55
5.06
5.33
5.69
6.31
6.91
7.54
$LUÀRZ>&)0@
638.4
722.5
789.4
882
645
860
860
860
Enclosure
IP00
Table 1-4 Ratings of MD290T315G to MD290T450G and MD290T355P to MD290T500P
Voltage Class
380 to 480 VAC
Model: MD290Txxxx(-L)**(-INT)
315G
355P
355G
400P
400G
450P
450G
500P
Drive Input
Rated Input Voltage
Three-phase 380 to 480V, -15% to +10%
Rated Input Current [A]
565
624
617
708
687
782
782
840
Power Capacity, [kVA]
517
571
565
647
629
715
716
768
Rated input frequency
50/60 Hz, ±5%
Drive Output
Applicable Motor, [kW]
315
355
355
400
400
450
450
500
Output Current, [A]
585
650
650
725
725
820
820
880
Default carrier frequency, [kHz]
3
3
3
3
3
3
3
3
Overload Capacity
G type: 150% for 60 Sec (For MD290T450G, the capacity is 130%.)
P type: 110% for 60 Sec
Max. output voltage
Three-phase 380 to 480 VAC (proportional to input voltage)
Max. output frequency
500 Hz
Braking
Resistor
Recommended Power, [kW]
54
60
69
69
78
78
87
87
Recommended Resistance,
PLQ>@
2.1
1.9
1.7
1.7
1.5
1.5
1.3
1.3
Thermal
Design
Thermal design power, [kW]
4.15
4.55
5.06
5.33
5.69
6.31
6.91
7.54
$LUÀRZ>&)0@
638.4
722.5
789.4
882
645
860
860
860
Enclosure
IP00
Note
: Model name with "L" in Table 1-3 and Table 1-4 means with the built-in AC output reactor
and cabinet.
Содержание MD290 Series
Страница 1: ......
Страница 79: ...3 Electrical Installation 78 3 ...
Страница 80: ...4 Operating Panel Keypad Display 4 1 Introduction 80 4 2 Inbuilt LED Operating Panel 80 ...
Страница 92: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 92 5 2 Setup Flowchart 93 ...
Страница 227: ...7 Interfaces and Communication 226 7 ...
Страница 285: ...10 Troubleshooting 284 11 ...
Страница 349: ......
Страница 350: ......