2. Mechanical Installation
- 23 -
2
2.2 Mounting Orientation and Clearance
Ƶ
Mounting Orientation
Always mount the AC drive in an upright position.
Ƶ
Mounting Clearance
The mechanical clearance varies with the power ratings of the AC drive.
Figure 2-1 Correct mounting clearance of MD290T18.5G/22P to MD290T160G/200P
B
B
A
A
C
Upright
(Side View)
(Front view)
18.5 to 22 kW
Power Rating
30 to 37 kW
45 to 160 kW
A
10 mm
A
50 mm
A
50 mm
B
200 mm
B
200 mm
B
300 mm
C
40 mm
C
40 mm
C
40 mm
Clearance Requirements
Figure 2-2 Correct mounting clearance of MD290T200G to MD290T450G and MD290T220P to
MD290T500P
B2
A2
D
Upright
Power Rating
Clearance Requirements (Unit: mm)
(Side view)
(Front view)
200 to 450 kW
A2
10 B2
250 C2
20
C2
D
20