User’s Manual
C166S V1 SubSystem
General Purpose Timer Unit
User’s Manual
12-41
V 1.6, 2001-08
Timer Block 2 Capture/Reload Register CAPREL in Reload Mode
This 16-bit register can be used as a reload register for core Timer T6. This mode is
selected by setting bit T6SR in register T6CON. The event causing a reload in this mode
is an overflow or underflow of core Timer T6.
When Timer T6 overflows from FFFF
H
to 0000
H
(when counting up) or underflows from
0000
H
to FFFF
H
(when counting down), the value stored in register CAPREL is loaded
into Timer T6. This will not drive the interrupt request line CRIRQ associated with the
CAPREL register. However, interrupt request line T6IRQ will be driven at high level to
indicate the overflow/underflow of T6.
Figure 12-24 Timer Block 2 Register CAPREL in Reload Mode
Core Timer T6
Up/Down
T6IRQ
MCB02045_b
T6OTL
T6SR
CAPREL Register
T6OFL
T6R
Prescaler
T6l
f
clk
BPS2
T6OE
T6OUT
MUX
0
1
1
Содержание C166S V1 SubSystem
Страница 10: ...User s Manual C166S V1 SubSystem User s Manual I 6 V 1 6 2001 08...
Страница 16: ...User s Manual C166S V1 SubSystem Introduction User s Manual 1 6 V 1 6 2001 08...
Страница 126: ...User s Manual C166S V1 SubSystem Central Processing Unit User s Manual 3 96 V 1 6 2001 08...
Страница 178: ...User s Manual C166S V1 SubSystem Memory Organization User s Manual 4 52 V 1 6 2001 08...
Страница 206: ...User s Manual C166S V1 SubSystem Instruction Set User s Manual 5 28 V 1 6 2001 08...
Страница 306: ...User s Manual C166S V1 SubSystem Detailed Instruction Set User s Manual 6 100 V 1 6 2001 08...
Страница 362: ...User s Manual C166S V1 SubSystem The External Bus Interface User s Manual 8 40 V 1 6 2001 08...
Страница 452: ...User s Manual C166S V1 SubSystem General Purpose Timer Unit User s Manual 12 44 V 1 6 2001 08...
Страница 454: ...User s Manual C166S V1 SubSystem Instruction Index User s Manual 13 2 V 1 6 2001 08...
Страница 459: ......