SEL-1FS1/SEL-2FS1 and SEL-1XD1/SEL-2XD1
Installation and Operation Manual
Installation, Operation, and Specifications
© 2015 Imagine Communications Corp.
Proprietary and Confidential.
Version 2.8 | Page 123
The diagram
describes the acceptable limits of defects in a fiber connection.
Figure 66:
Fiber Optic Cross-Section
Inspection and Cleaning Procedure
The following topics are covered in this section:
•
Inspection (on page
123
)
•
Dry Cleaning (on page 124)
•
Wet Cleaning (on page 124)
Inspection
To inspect and clean the fibers, follow these steps:
1.
Ensure the fiber is not "live."
WARNING!
Eye damage may occur if an optical instrument such as a microscope, magnifying glass, or eye loupe
is used to stare at an energized fiber end.
2.
Inspect the fiber endface with a fiberscope.
3.
If the fiber endface is clean, return to the installation instructions.
If the connector is dirty, proceed to the dry cleaning instructions below.