![Imagine Panacea Lite Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/imagine/panacea-lite/panacea-lite_operation-manual_2045417145.webp)
Chapter 4
P12×1-SP Installation, Configuration, and Operation
126
Copyright © 2004-2007, 2008, 2010, Harris Corporation
When bit 5 is ON, the TANDBERGTOLXY will internally substitute the
disconnect code 000 (or 00) with the value for Source 1. In this mode, a
disconnect request will always result in a connection to Source 1.
When bit 5 is OFF, the TANDBERGTOLXY will make no internal substitutions
for the disconnect code; the destination will be disconnected from all sources.
Three-Digit
Formatting (SW1
Pole 6)
The SW1 Pole 6 bit provides a selectable parameter “native” to Sandar Prosan
protocol, which allows you to specify how many digits (2 or 3) with which values
for Matrix and Status Response messages are formatted. The factory default is to
set this bit to the ON position.
When bit 6 is ON, source and destination values will be formatted with 3 digits
(for example: 001).
Here is an example of a Status response message formatted in 3-digit
mode: SA:001,002,003,004,005,006,007,008.
Here is an example of a Matrix message formatted in 3-digit mode:
M001:001,002,003,004,005,006,007,008.
When bit 6 is OFF, source and destination values will be formatted with 2 digits
(for example: 01).
Here is an example of a Status response message formatted in 3-digit
mode: SA:01,02,03,04,05,06,07,08.
Here is an example of a Matrix message formatted in 3-digit mode:
M01:01,02,03,04,05,06,07,08.
Device IDs (SW1
Poles 7 and 8)
The SW1 Poles 7 and 8 provides a selectable address range. Sandar Prosan
protocols require a device to have two addresses starting at the value 8200. The
addresses are referred to as the Poll Address (which is always odd) and the Data
Address (which is always even).
The Harris Device ID (which is seen by Harris products on the X-Y bus) is the
DIP switch value (see
Table 4-25
on page 126).
The Poll Address of the P12×1-SP is the constant value 8200 added to the DIP
switch value selected (see
Table 4-25
on page 126).
The Data Address is equal to the Poll Address plus 1 (see
Table 4-25
on
page 126).
Table 4-25
shows SW1 poles 7 and 8 DIP switch settings with corresponding
Harris device IDs, Poll Addresses, and Data Addresses.
Table 4-25
TANDBERGTOLXY Device IDs
SW1 Poles 7 / 8
DIP Switch
settings
Harris Device ID
(DIP Switch
value)
Poll Address
Data Address
00
01
8201
8202
01
03
8203
8204
10
05
8205
8206
11
07
8207
8208
Содержание Panacea Lite
Страница 19: ...Preface xviii Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 29: ...Chapter 1 Introduction 10 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 43: ...Chapter 2 Frame Configuration and Installation 24 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 47: ...Chapter 3 Frame Operation 28 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 157: ...Chapter 4 P12 1 SP Installation Configuration and Operation 138 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 197: ...Appendix B Control Panel Installation and Operation 178 Copyright 2004 2007 2008 2010 Harris Corporation...