Chapter 4
P12×1-SP Installation, Configuration, and Operation
104
Copyright © 2004-2007, 2008, 2010, Harris Corporation
The P12×1-SP sends status command to the X-Y in these conditions:
1
Power Up
When the P12×1-SP is first powered up, it will send the complete status of all
device functions to the X-Y port.
2
Status Change
The P12×1-SP is updating the device’s status every 1/10 second. When a
function changes its status, it sends the status change command only with the
ID for functions which have been changed.
For example, if PLAY has been changed from one to zero and STOP changed
from zero to one, the following commands are sent:
K!<Device ID>,Z:04
K!<Device ID>,O:09
3
A Request of Status Update is Received
When the X-Y port receives the Status Update command, a complete status of
the device is sent to the X-Y port.
The Status Update command is as follows:
K:<Device ID>,S9
17.....
CF Mode
35.....
Svo Alarm
18.....
Freeze On
36.....
CF Lock
19.....
Auto Mode
37.....
EOT
1A.....
Preroll
38.....
Near EOT
1B.....
Preview
39.....
Lost Lock
1C.....
Auto Edit
3A.....
Buzzer
1D.....
Review
3B.....
Fnc Abort
1E.....
Edit
3C.....
Mark On
Table 4-21
Status Update Report Functions
(Continued)
Function
Description
Function
Description
Содержание Panacea Lite
Страница 19: ...Preface xviii Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 29: ...Chapter 1 Introduction 10 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 43: ...Chapter 2 Frame Configuration and Installation 24 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 47: ...Chapter 3 Frame Operation 28 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 157: ...Chapter 4 P12 1 SP Installation Configuration and Operation 138 Copyright 2004 2007 2008 2010 Harris Corporation...
Страница 197: ...Appendix B Control Panel Installation and Operation 178 Copyright 2004 2007 2008 2010 Harris Corporation...