EN
8 - TROUBLES - CAUSES - SOLUTIONS
Boss 338HD - 552HD
8 - Pag. 2 / 2
8.1 GENERAL
FAILURES
TROUBLES CAUSES SOLUTIONS
The bar feeder cannot start
No power.
Check the electrical connection.
Open guard.
Close the guard.
Emergency systems on.
Disconnect the emergency devices.
Motor thermal circuit breaker
burnt.
Reset the thermal circuit breaker
with the special buttons.
The bar feeder has been reset
but the automatic cycle will not
start.
No lathe signal.
Check the electrical connection with
the lathe.
The pneumatic devices do not
respond to controls.
No air.
Check the air system.
The first feeding and feeding
are stopped unexpectedly.
Motor thermal circuit breaker
burnt.
Reset the motor circuit breaker with
the special buttons.
8.2
BAR MAGAZINE – Failures
TROUBLES CAUSES SOLUTIONS
During the loading operation
the bar cannot be inserted into
the magazine
The bar alignment plates are
too low
Adjust the position of the plates
The first bar in the magazine
fails to drop into the guide
channels
The bar alignment plates are
not properly adjusted.
Adjust the bar alignment plates
Содержание BOSS 338 HD
Страница 2: ......
Страница 4: ......
Страница 15: ...1 GENERAL INFORMATION Boss 338HD 552HD EN 1 Pag 5 5 ...
Страница 16: ......
Страница 46: ......
Страница 60: ......
Страница 110: ...EN 5 ADJUSTMENTS AND SETUP Boss 338HD 552HD 5 Pag 18 18 Restore the machining cycle of the bar feeder ...
Страница 120: ......
Страница 124: ...EN 6 USE AND OPERATION Boss 338HD 552HD 6 Pag 4 4 ...
Страница 141: ...6 USE AND OPERATION Boss 338HD 552HD EN 6 Pag 21 21 Turn the main power switch to O OFF ...
Страница 154: ......
Страница 158: ......
Страница 164: ......
Страница 168: ...EN 10 LIST OF CUSTOMER SERVICE CENTRES Boss 338HD 552HD 10 Pag 4 4 Valid only for front remnant ejection ...
Страница 190: ...EN 11 COLLETS Boss 338HD 552HD 11 Pag 10 10 ...
Страница 214: ......