Fig. 19 – Interface panel on the rear side of the IBIS-ArcSAR Supply Unit
The I/O interfaces panel shown on front of Fig. 18
MAINS INPUT (100-240 Vac 50-60 Hz – 7 A) AC Mains connection;
AC OUTPUT (230 Vac 50 Hz 10 A): 230 Vac outlet for supplying
auxiliary equipment (only when the onboard generator is on);
WIND: socket for Wind Turbine;
DC INPUT: connection for external battery pack;
WEATHER STATION: socket for IBIS Weather Station;
PREHEATING: socket for preheating system (low temperature kit)
SOLAR (12 Vdc – 2 A): a plug for a solar panel which could be used to
charge the Genset battery;
LAN 1: Ethernet port connected to router LAN port;
WAN: Ethernet port connected to router WAN port;
LAN 2: Ethernet port connected to router LAN port;
AUX1 (12, 24, 48 Vdc – 4 A) outlet;
TRAILER SUPPLY (12 Vdc – 10 A) cable socket;
AUX2 (12, 24, 48 Vdc – 2 A) outlet;
Fig. 20 – Interface panel on the front side of the ArcSAR Supply Unit
The I/O interfaces panel placed on the front side includes (from left to right
in
SOCKET POSITIONER: this socket allows the power supply and control
of the acquisition unit (sensor, positioner, cameras and GPS)
EV CAMERA section: not applicable to the ArcSAR system