5.3
Lubricants.
The recommended synthetic gearbox grease for use in the RTP
TM
is one that
is intended for ‘sealed’ units. Suitable for operating temperatures between
20°C and 120°C (-4°F to 248°F) and a base viscosity in the region of 150 Cst
at 40°C (104°F).
The recommended gearbox oil for use in the RTP
TM
is an “EP (Extreme
Pressure) grade gear lube”. The following grades should be used in these
temperature ranges:
EP150
-18 to 0°C
(0 to 32°F)
EP220
0 to 30°C
(32 to 85°F)
EP320
30°C and higher.
(85°F and higher)
Care should be taken not to overfill the gearbox.
Refer to manufacturers recommended operating conditions concerning
limitations, servicing and application. In case of doubt, please consult the
factory with details.
Approximate gearbox capacity when pump inlet/outlet ports are orientated in:
Horizontal Plane
Vertical Plane
litres
US Gallons
litres
US Gallons
RTP 20
1.1
0.29
1.1
0.29
RTP 30
0.575
0.15
0.575
0.15
G
G
r
r
e
e
a
a
s
s
e
e
O
O
i
i
l
l
Содержание Wright Flow Technologies RTP Series
Страница 1: ...P Pa ag ge e 0 0 INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR THE RANGE OF PUMPS...
Страница 47: ...P Pa ag ge e 4 46 6 5 0 Specifications 5 1 Clearance Chart B A C Radial D C Radial...
Страница 51: ...P Pa ag ge e 5 50 0 B B 100 mm or 4 PORT 80 mm or 3 PORT 5 5 RTP30 Foundation Dimensions Stub Shaft Drive...
Страница 54: ...P Pa ag ge e 5 53 3 5 6 Typical Basic Pump Build RTP20 Shown...
Страница 56: ...P Pa ag ge e 5 55 5 5 8 RTPTM Service History Pump Serial No Date Comments...