P
P
a
a
g
g
e
e
1
1
9
9
3.7
Heating and Cooling Devices
See Fig 8.
The RTP
TM
model can be supplied with a jacketed front cover and rotorcase
with ports for circulation of a heating/cooling media. The jacketed front cover
and rotorcase heating and cooling ports are strategically positioned such that
the required thermal effect acts on the pumping chamber and product seal
area.
The pressure rating of the RTP
TM
jacketed front cover and rotorcase
heating/cooling ports are 3.5 bar g (50 psi) and should not be exceeded
without consulting Wright Flow Technologies Limited or your local Wright Flow
Technologies Limited distributor.
Heating/cooling of the pump head is used to maintain, rather than
increase/decrease the temperature of the pumped media and should be used
as part of a complete system where suction and discharge lines and vessels
are also heated/cooled.
Содержание Wright Flow Technologies RTP Series
Страница 1: ...P Pa ag ge e 0 0 INSTALLATION OPERATION AND MAINTENANCE MANUAL FOR THE RANGE OF PUMPS...
Страница 47: ...P Pa ag ge e 4 46 6 5 0 Specifications 5 1 Clearance Chart B A C Radial D C Radial...
Страница 51: ...P Pa ag ge e 5 50 0 B B 100 mm or 4 PORT 80 mm or 3 PORT 5 5 RTP30 Foundation Dimensions Stub Shaft Drive...
Страница 54: ...P Pa ag ge e 5 53 3 5 6 Typical Basic Pump Build RTP20 Shown...
Страница 56: ...P Pa ag ge e 5 55 5 5 8 RTPTM Service History Pump Serial No Date Comments...