©HALE PRODUCTS, INC. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
WARNING
ONCE A NOZZLE HAS BEEN SELECTED IT IS IMPERATIVE TO PROVIDE AMPLE TRAINING IN
THE USE OF THE NOZZLE. OPEN CAFS NOZZLES SLOWLY AND MAKE SURE THE NOZZLE IS
SECURED AGAINST REACTION FORCE.
•
Do not remove the cap from the FS series water strainer from the CAFS system while the unit
is running.
•
Projectiles can cause injury. DO NOT use a blank hose cap on CAFS discharges. CAFS stores
energy in the form of compressed air in the piping that could turn a blank hose cap into a
projectile when removed.
•
DO NOT perform maintenance on the CAFS system while the unit is running. Make sure the
system is shut down and components have cooled before attempting maintenance.
•
The operating pressure range of the CAFS system is 75-150 PSI [5.1-10.3 Bar]. DO NOT
EXCEED 150 PSI (10.3 BAR).
CAUTION
THE PROPER OIL LEVEL MUST BE MAINTAINED IN THE AIR COMPRESSOR SYSTEM AT ALL
TIMES. LOW OIL LEVEL OR NO OIL COULD RESULT IN EXCESSIVE COMPRESSOR
TEMPERATURE AND POSSIBLE COMPRESSOR FIRE. OVER FILLING COMPRESSOR SYSTEM
CAN RESULT IN SYSTEM MALFUNCTIONING.
THE FIRE PUMP IS EQUIPPED WITH A MECHANICAL SEAL. DO NOT RUN PUMP DRY FOR
EXTENDED PERIODS OF TIME OR SEAL DAMAGE COULD RESULT.
DO NOT EXCEED 220
o
F [105
o
C] DURING COMPRESSOR SYSTEM OPERATION AS INDICATED
BY THE RED INDICATOR LAMP ON THE PANEL.
•
DO NOT remove or alter any guard or insulating devices or attempt to operate the system
when these guards are removed. Make sure all access/service panels and covers are
installed, closed and latched tight where applicable.
•
DO NOT remove or alter any hydraulic or pneumatic connections, electrical devices, etc. DO
NOT tamper with or disconnect safety features or modify protective guards (such as covers or
doors). DO NOT add or remove structural parts.
NOISE
Operators must wear suitable EAR PROTECTION when the pump is running.
GAUGES
Do not clean the glass surfaces of the gauges with abrasive or solvent cleaners. These will cloud the
glass surface. Use a mild detergent and water.
CLUTCH ENGAGEMENT
Clutch must be engaged between engine idle and engine 900 RPM to ensure clutch longevity.
Содержание HALE SmartCAFS
Страница 106: ......