©HALE PRODUCTS, INC. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
(z)
“+” and “-“ buttons
Change the value of the currently selected menu item.
(aa) Exit button
Exit the menu.
(bb) Save button
Save all items in the menu.
OEM MENU
Enter the password
2314
in the system menu’s keyboard to open the user menu. The user
menu allows setting of user configurable items.
Page one
Page two
Tank-to-pump timing (open) - select the amount of time the “open” air solenoid is activated. The
tank-to-pump valve is controlled via a linear air cylinder so this setting
allows for fine tuning of the amount of time it actually takes to fully stroke
the cylinder.
Default: 6 seconds
Tank-to-pump timing (close) - select the amount of time the “close” air solenoid is activated. The
tank-to-pump valve is controlled via a linear air cylinder so this setting
allows for fine tuning of the amount of time it actually takes to fully stroke
the cylinder.
Default: 4 seconds
Foam tank selector type
- select the foam tank selector type. Single tank systems (none or
MST), dual tank systems (MDT or ADT).
Default: MST
Low voltage warning (12V) - select the low voltage warning level for 12V systems.
Default: 11.9 volts
Low voltage warning (24V) - select the low voltage warning level for 24V systems.
Default: 23.8 volts