Page
111
of
116
©HALE PRODUCTS, INC. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
PART
NUMBER
538-00107-000
DESCRIPTION
Cooler Valve
OPERATION
Cooling water from the heat exchanger
designed to cool the compressor is
plumbed to the tank. When not running
CAFS (i.e. drafting), the tank can overfill.
This solenoid/valve assembly is designed
to be flowing when the clutch solenoid is
engaged.
POSSIBLE
FAULT
•
Not opening
o
No air to 4-way valve.
o
Air ports clogged.
o
No signal from clutch solenoid.
PART
NUMBER
038-1390-00-0
DESCRIPTION
Thermostatic Oil Bypass Valve
OPERATION
Opens at 150°F (65°C) [fully opening at
170°F (76°C)] to allow the oil to run
through the heat exchanger otherwise it
bypasses the heat exchanger.
POSSIBLE
FAULT
•
Compressor is overheating
o
Not fully opening.
o
Oil temperature is above max
operating temperature.
PART
NUMBER
108-0630-00-0
DESCRIPTION
Oil Separator
OPERATION
Separates the air and oil through a series
of chambers internally and any
condensation/water, which can be
drained from the bottom ball valve. The
side “arm” is for replacing oil. The top port
with the air valve is for discharging air to
the pump or auxiliary port. The hex on the
side supplies air to the control system for
the compressor.
POSSIBLE
FAULT
•
Compressor is overheating
o
Oil is not at proper level.
o
Oil not being cooled by Heat
Exchanger.
o
Coolant Valve not opening.
•
Air injection/Pressure match
o
Hex port on side is leaking
o
Brass orifice is missing from
scavenge line.