Page
79
of
116
©HALE PRODUCTS, INC. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
AIR COMPRESSOR MOISTURE DRAIN
After the air compressor system is used and has had time to COOL to ambient temperature,
accumulated moisture must be drained from the oil reservoir separator.
Drain Moisture
To drain the moisture from the system, locate the oil and moisture drain valve on the bottom of the
oil reservoir separator. See: “MAJOR COMPONENTS AND CONTROLS” on page
1. Place a suitable container 8 to 10 ounces (237 to 296 ml) under the compressor drain valve and
remove the brass valve plug.
2. Open the valve and allow the water to drain. The oil drain valve is a 1/4” NPT ball valve.
3. Monitor the flow. As soon as pure oil begins flowing, CLOSE the valve.
4. Replace the brass valve plug in the valve and check the oil level.
ATTENTION
DISPOSE OF THE WASTE WATER/OIL IN ACCORDANCE WITH YOUR LOCAL RECYCLING
REGULATIONS.
Note:
In humid weather, after short run times, up to 8 ounces (237 ml) of condensation could
accumulate. Running the compressor for longer periods automatically removes moisture through
the discharge with the air and heating of the oil.