©HALE PRODUCTS, INC. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
•
A quick disconnect and ball valve should be installed on the panel to control air flow from
aux air outlet.
COMPRESSOR OIL SERVICE ACCESS
•
To allow access for compressor and pump servicing, a panel with approximately 450 square
inches of area and no dimension less than 18” (457 mm) must be provided.
•
Include a service door to inspect the receiver tank oil level and provide access to the oil fill
fitting. The service door should measure 14” x 14” (356mm) minimum. See figure below.
CAUTION
DO NOT REMOTE CONNECT OR
EXTEND THE OIL FILL LINE. EXTENDING
THIS LINE ALLOWS FOR POSSIBLE
OVERFILL WHICH WILL CAUSE SERIOUS
DAMAGE TO THE COMPRESSOR.
Affix the WARNING / CAUTION decal
(Hale P/N 101-1410-01-0) to the inside of
the receiver tank service door.
Figure 28: Service Panel Example