Page
89
of
116
©HALE PRODUCTS, INC. Our policy is one of continuous development. We therefore
reserve the right to amend specifications without notice or obligation.
CAFS - SETTING THE AIR BALANCE CONTROL VALVES
1. Symptoms of Improper Adjustment
a. Air pressure fluctuates or bounces too far from water pressure on the duplex gauge:
i. The snubber valve is open too much
b. A “popping” sound is observed within the air intake filter & ducting:
i. The snubber valve is closed too much.
2. Functionally Test Smart CAFS Air Pressure /Water Pressure & Adjust Match
a. The water pump should be running at 700-800 RPM and discharging water.
b. Turn system ON by pressing
. LED bar graph on display should light up and foam
should start pumping.
c. Close the discharge valve completely on the CAFS manifold.
d. While observing the duplex gauge, engage compressor clutch with the
BLUE AIR
power
button
and increase engine speed and pump pressure to 75 PSI. Air pressure
should follow & match while maintaining a stable reading.
e. Adjust the flow valve located on the side of the air intake to increase or decrease the air
flow/pressure for the compressor. Adjust the snubber valve on intake valve body
(located on the top of the air compressor) to dampen out pulses and fluctuations to
achieve smooth operation as indicated on the duplex gauge.
f. Lock in place with lock nut. Repeat for “g” through “i” to fine tune compressor air
pressure/water pressure match.