FC6A S
ERIES
MICROS
MART
L
ADDER
P
ROGRAMMING
M
ANUAL
FC9Y-B1726
18-35
18: P
ULSE
O
UTPUT
I
NSTRUCTIONS
RAMPL34 Instruction (Reversible Control Enabled, Dual-pulse Output) Timing Chart
When data register D0200 is specified for S1 and internal relay M0050 is specified for D1 of the RAMPL34
instruction in order to move from the current position (2000, -1000) to the target position (-2000, -3000)
•
When the RAMPL34 instruction input is turned on, pulses are output according to the settings configured by the control registers. X axis
reverse pulses are output from Q5 and Y axis reverse pulses are output from Q7 in order to move both X and Y axes in reverse.
•
When pulse output starts, M0050 turns on. M0052 turns on while the pulse frequency is increasing or decreasing.
•
The steady pulse frequency and initial pulse frequency of each axis are calculated from the preset value, combined steady pulse frequency,
and combined initial pulse frequency, and then the pulses are output for each axis so that the frequency reaches the steady pulse frequency
from the initial pulse frequency in the frequency change time. When the frequency change time is specified as 100, the steady pulse
frequency is reached in 100 ms by increasing or decreasing the frequency every 10 ms.
•
Pulse output stops when the pulses calculated from the difference between the current position and the target position are output. (The
number of pulses is also counted while changing the frequency.) At this time, M0050 turns off and M0051 turns on.
•
If the RAMPL34 instruction input turns off during pulse output, pulse output stops. If the input turns on again, the operation starts from the
beginning.
•
Even if the contents of the data registers are changed during pulse output, the change is not reflected in pulse output operation. The
changed content is reflected the next time the RAMPL34 instruction is started.
D1
M0050
S2
M0000
RAMPL
34
S1
D0200
RAMPL34
instruction input
Y [pulses]
Current position
(2000, -1000)
Target position
(-2000, -3000)
X axis movement distance
and direction
Y axis movement distance
and direction
X [pulses]
RAMPL34 instruction
input
X axis reverse
pulse frequency
X axis forward
pulse frequency
Q5
Pulse output
ON
M0050
Pulse output
complete
M0051
Y axis reverse
pulse frequency
Q7
Pulse output
status
M0052
Q4
Y axis forward
pulse frequency
Q6
Frequency
change time
Frequency
change time
Содержание MICROSmart FC6A Series
Страница 1: ...B 1726 7 FC6A SERIES Ladder Programming Manual ...
Страница 8: ...Preface 7 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 32: ...1 OPERATION BASICS 1 20 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 96: ...3 INSTRUCTIONS REFERENCE 3 18 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 130: ...4 BASIC INSTRUCTIONS 4 34 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 158: ...6 DATA COMPARISON INSTRUCTIONS 6 10 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 192: ...9 SHIFT ROTATE INSTRUCTIONS 9 12 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 216: ...10 DATA CONVERSION INSTRUCTIONS 10 24 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 248: ...11 WEEK PROGRAMMER INSTRUCTIONS 11 32 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 272: ...12 DISPLAY INSTRUCTIONS 12 24 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 284: ...14 REFRESH INSTRUCTIONS 14 6 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 288: ...15 INTERRUPT CONTROL INSTRUCTIONS 15 4 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 294: ...16 COORDINATE CONVERSION INSTRUCTIONS 16 6 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 374: ...18 PULSE OUTPUT INSTRUCTIONS 18 78 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 Setting ...
Страница 450: ...20 DUAL TEACHING TIMER INSTRUCTIONS 20 4 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 502: ...25 DATA LOG INSTRUCTIONS 25 22 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 546: ...26 SCRIPT 26 44 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 574: ...27 FLOW CALCULATION INSTRUCTIONS 27 28 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 583: ...FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 28 9 28 USER DEFINED MACRO INSTRUCTION ...
Страница 584: ...28 USER DEFINED MACRO INSTRUCTION 28 10 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Страница 598: ...APPENDIX A 14 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...