Selecting a RAID level and tuning performance
Disk arrays are used to improve performance and reliability. The amount of
improvement depends on the application programs that you run on the server and
the RAID levels that you assign to the logical drives.
Each RAID level provides different levels of fault-tolerance (data redundancy),
utilization of physical drive capacity, and read and write performance. In addition,
the RAID levels differ in regard to the minimum and maximum number of physical
drives that are supported.
When selecting a RAID level for your system, consider the following factors.
RAID level
Data
redundancy
Physical drive
capacity
utilization
Read
performance
Write
performance
Built-in
spare
drive
Min.
number
of drives
Max.
number
of drives
RAID level-0
No
100%
Superior
Superior
No
1
16
RAID level-1
Yes
50%
Very high
Very high
No
2
2
RAID level-1E
Yes
50%
Very high
Very high
No
3
16
RAID level-5
Yes
67% to 94%
Superior
High
No
3
16
RAID level-5E
Yes
50% to 88%
Superior
High
Yes
4
16
RAID level-00
No
100%
Superior
Superior
No
2
60
RAID level-10
Yes
50%
Very high
Very high
No
4
60
RAID
level-1E0
Yes
50%
Very high
Very high
No
6
60
RAID level-50
Yes
67% to 94%
Superior
High
No
6
60
Physical drive utilization, read performance, and write performance depend on the
number of drives in the array. Generally, the more drives in the array, the better the
performance.
Supported RAID levels
The ServeRAID controllers support RAID level-0, level-1, level-1E, level-5, level-5E,
level-00, level-10, level-1E0, and level-50.
The integrated RAID controllers support RAID level-1 only. The ServeRAID-5i
controller does not support RAID level-5E.
22
IBM ServeRAID: User’s Reference, Version 5.10
Содержание ServeRAID
Страница 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Страница 10: ...x IBM ServeRAID User s Reference Version 5 10...
Страница 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Страница 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Страница 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Страница 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Страница 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Страница 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Страница 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Страница 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Страница 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Страница 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Страница 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Страница 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Страница 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Страница 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Страница 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Страница 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Страница 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Страница 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Страница 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Страница 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Страница 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Страница 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Страница 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Страница 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Страница 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Страница 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Страница 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Страница 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Страница 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Страница 225: ......
Страница 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...