BCS
ECS
Explanation
Action
07
0C
Online/rebuild drives are not responding,
and a drive was found at the incorrect SCSI
ID.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
Note:
Pressing F4 might not correct the
problem. If you do not return the drives and
cables to the previous configuration, the
message might return.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
3. To modify the configuration and accept the
rearrangement of the physical drives, press
F6.
To exit without making changes, press F10.
07
1C
Online/rebuild and hot spare/standby
hot-spare drives are not responding, and a
drive was found at the incorrect SCSI ID.
07
2C
Online/rebuild and ready/standby drives are
not responding, and a drive was found at
the incorrect SCSI ID.
07
3C
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, and a drive was found at the
incorrect SCSI ID.
07
4C
Online/rebuild drives are not responding,
and a drive was found at the incorrect SCSI
ID, and unidentified drives were found.
07
5C
Online/rebuild and hot spare/standby
hot-spare drives are not responding, a drive
was found at the incorrect SCSI ID, and
unidentified drives were found.
07
6C
Online/rebuild and ready/standby drives are
not responding, a drive was found at the
incorrect SCSI ID, and unidentified drives
were found.
07
7C
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, a drive was found at the
incorrect SCSI ID, and unidentified drives
were found.
07
18
Online/rebuild and hot spare/standby
hot-spare drives are not responding.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
To exit without making changes, press F10.
07
28
Online/rebuild and ready/standby drives are
not responding.
07
38
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding.
07
48
Online/rebuild drives are not responding,
and unidentified drives were found.
07
58
Online/rebuild and hot spare/standby
hot-spare drives are not responding, and
unidentified drives were found.
07
68
Online/rebuild and ready/standby drives are
not responding, and unidentified drives were
found.
07
78
Online/rebuild, ready/standby, and hot
spare/standby hot-spare drives are not
responding, and unidentified drives were
found.
09
00
No error occurred.
No action is required. Press F10 to exit without
making any changes.
154
IBM ServeRAID: User’s Reference, Version 5.10
Содержание ServeRAID
Страница 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Страница 10: ...x IBM ServeRAID User s Reference Version 5 10...
Страница 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Страница 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Страница 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Страница 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Страница 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Страница 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Страница 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Страница 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Страница 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Страница 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Страница 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Страница 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Страница 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Страница 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Страница 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Страница 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Страница 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Страница 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Страница 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Страница 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Страница 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Страница 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Страница 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Страница 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Страница 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Страница 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Страница 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Страница 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Страница 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Страница 225: ......
Страница 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...