BCS
ECS
Explanation
Action
09
10
Hot spare/standby hot-spare drives are not
responding.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
To exit without making changes, press F10.
09
20
Ready/standby drives are not responding.
09
30
Hot spare/standby hot-spare and
ready/standby drives are not responding.
0F
00
No error occurred.
No action is required. Press F10 to exit without
making any changes.
0F
10
Hot spare/standby hot-spare drives are not
responding.
To correct the problem:
1. To keep the previous configuration in the
controller, replace the physical drives and
cable connections that were switched or
moved; then, press F4 to retry.
2. If all the physical drives are present and
connected correctly, one or more of the drives
might be defective. Identify and replace the
defective drives; then, press F5 to accept the
changes.
To exit without making changes, press F10.
0F
20
Ready/standby drives are not responding.
0F
30
Hot spare/standby hot-spare and
ready/standby drives are not responding.
Recovering from problems starting the ServeRAID Manager
Problem
Explanation
Action
The ServeRAID Manager program
hangs on the splash screen.
You might be using an old
version of the ServeRAID
device driver.
Upgrade the ServeRAID device driver to the
latest version. See Chapter 5, “Installing
ServeRAID device drivers” on page 49 for
more information.
When starting the ServeRAID Manager,
the following error message is
displayed:
Unable to find load file RAIDMAN
The ServeRAID Manager
program was not installed to
the root directory of the
SYS volume.
Reinstall the ServeRAID Manager. If the
installation is completed properly, there will be
a directory called RAIDMAN under the root
directory of the SYS volume.
When starting the ServeRAID Manager,
the following error message is
displayed:
-autounload is an invalid parameter
You are using an old
version of the Novell Java
Virtual machine (JVM).
Download and install the latest JVM from the
Novell Web site:
http://developer.novell.com/ndk/download.htm
When starting the ServeRAID Manager,
the following error message is
displayed:
ERROR: Unable to find Java
The Novell Java Virtual
machine (JVM) is not
installed on your server.
Download and install the latest JVM from the
Novell Web site:
http://developer.novell.com/ndk/download.htm
Chapter 18. Solving ServeRAID problems
155
Содержание ServeRAID
Страница 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Страница 10: ...x IBM ServeRAID User s Reference Version 5 10...
Страница 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Страница 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Страница 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Страница 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Страница 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Страница 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Страница 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Страница 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Страница 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Страница 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Страница 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Страница 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Страница 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Страница 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Страница 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Страница 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Страница 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Страница 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Страница 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Страница 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Страница 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Страница 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Страница 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Страница 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Страница 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Страница 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Страница 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Страница 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Страница 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Страница 225: ......
Страница 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...