Drive state
Meaning
Critical
A RAID level-1, level-1E, level-5, or level-5E logical drive that contains a defunct physical
drive is in the critical state. A critical logical drive is accessible, despite a physical drive
failure.
Attention:
If the state of the logical drive is critical, see “Rebuilding a defunct drive” on
Migrating
The logical drive is undergoing a logical-drive migration; that is, a change in RAID levels, a
change in logical-drive size, an increase in free space, or a RAID level-5E compression or
decompression.
Offline
The logical drive is offline and not accessible. This state occurs when one of the following is
true:
v
One or more physical drives in a RAID level-0 logical drive are defunct.
v
Two or more physical drives in a RAID level-1, level-1E, or level-5 logical drive are defunct.
v
Three or more drives in a RAID level-5E logical drive are defunct.
If any of these is true, see “Rebuilding a defunct drive” on page 157.
Okay
The logical drive is working properly. It is in a good, functional state.
System
The ServeRAID controller uses this reserved state during logical-drive migration.
Chapter 3. Understanding RAID technology
33
Содержание ServeRAID
Страница 1: ...IBM ServeRAID User s Reference Version 5 10 SC33 P263 60...
Страница 10: ...x IBM ServeRAID User s Reference Version 5 10...
Страница 16: ...xvi IBM ServeRAID User s Reference Version 5 10...
Страница 17: ...Part 1 Installation and configuration Copyright IBM Corp 2002 1...
Страница 18: ...2 IBM ServeRAID User s Reference Version 5 10...
Страница 26: ...10 IBM ServeRAID User s Reference Version 5 10...
Страница 36: ...20 IBM ServeRAID User s Reference Version 5 10...
Страница 50: ...34 IBM ServeRAID User s Reference Version 5 10...
Страница 63: ...Figure 19 Hints and tips feature Chapter 4 Configuring ServeRAID controllers 47...
Страница 64: ...48 IBM ServeRAID User s Reference Version 5 10...
Страница 66: ...50 IBM ServeRAID User s Reference Version 5 10...
Страница 80: ...64 IBM ServeRAID User s Reference Version 5 10...
Страница 81: ...Part 2 Utility programs Copyright IBM Corp 2002 65...
Страница 82: ...66 IBM ServeRAID User s Reference Version 5 10...
Страница 86: ...70 IBM ServeRAID User s Reference Version 5 10...
Страница 116: ...100 IBM ServeRAID User s Reference Version 5 10...
Страница 117: ...Part 3 Installing the IBM ServeRAID Cluster Solution Copyright IBM Corp 2002 101...
Страница 118: ...102 IBM ServeRAID User s Reference Version 5 10...
Страница 122: ...106 IBM ServeRAID User s Reference Version 5 10...
Страница 126: ...110 IBM ServeRAID User s Reference Version 5 10...
Страница 134: ...118 IBM ServeRAID User s Reference Version 5 10...
Страница 150: ...134 IBM ServeRAID User s Reference Version 5 10...
Страница 155: ...Part 4 Maintenance and troubleshooting Copyright IBM Corp 2002 139...
Страница 156: ...140 IBM ServeRAID User s Reference Version 5 10...
Страница 158: ...142 IBM ServeRAID User s Reference Version 5 10...
Страница 190: ...174 IBM ServeRAID User s Reference Version 5 10...
Страница 193: ...Part 5 Appendixes Copyright IBM Corp 2002 177...
Страница 194: ...178 IBM ServeRAID User s Reference Version 5 10...
Страница 198: ...182 IBM ServeRAID User s Reference Version 5 10...
Страница 210: ...194 IBM ServeRAID User s Reference Version 5 10...
Страница 220: ...204 IBM ServeRAID User s Reference Version 5 10...
Страница 225: ......
Страница 226: ...Part Number 33P2636 Printed in U S A SC33 P263 60 1P P N 33P2636...