SAN32M1 Fabric Switch Installation and Service Manual
486
Event Code: 584
Message:
Not Operational primitive sequence (NOS) received
Severity:
Major
Explanation:
The Not-Operational Primitive Sequence (NOS) has been recognized by the incident node (see FC-PH clause
16.5.3.2).
Action:
A Link-incident Record (LIR) is generated and sent to the host using the link-incident reporting procedure defined
in the T11/99-017v0 document. If, after fault isolation is performed by the host, it is determined that the incident is
because of a port failure, perform a data collection procedure for this switch using the EFC Manager, and return
CD to IBM for analysis.
Event Data:
Byte 0 = Port number (00-8F)
Bytes 4-7 = Elapsed millisecond tick count
Bytes 8-11 = Port state indicators
0x00 = Active
0x01 = OLIB
0x05 = LR1
0x06 = LR2
0x07 = LR3
0x09 = LF2
0x0A = LF1
0x0C = OL1A
0x0D = OL1C
0x0E = OL2
0x0F = OL3.
Distribution:
Switch
EFC Server
Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log
Call-Home
Sense Info
Link Incident
✔
Содержание SAN32M1
Страница 1: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Страница 2: ......
Страница 3: ...IBM TotalStorage SAN32M1 Switch Installation and Service Manual GC26 7665 01...
Страница 12: ...SAN32M1 Fabric Switch Installation and Service Manual x...
Страница 18: ...SAN32M1 Fabric Switch Installation and Service Manual xvi...
Страница 20: ...SAN32M1 Fabric Switch Installation and Service Manual xviii...
Страница 82: ...SAN32M1 Fabric Switch Installation and Service Manual 50...
Страница 222: ...SAN32M1 Fabric Switch Installation and Service Manual 190...
Страница 418: ...SAN32M1 Fabric Switch Installation and Service Manual 386...
Страница 454: ...SAN32M1 Fabric Switch Installation and Service Manual 422...
Страница 532: ...SAN32M1 Fabric Switch Installation and Service Manual 500...
Страница 536: ...SAN32M1 Fabric Switch Installation and Service Manual 504...
Страница 625: ......
Страница 626: ...Printed in USA GC26 7665 01...