Preparing the system for operation after removing and replacing a
system fan
To prepare the system for operation after removing and replacing a system fan, complete the steps in this
procedure.
About this task
Procedure
1.
Ensure that you have the electrostatic discharge (ESD) wrist strap attached. If not, attach it now.
2.
If you performed a nonconcurrent repair, start the system. For instuctions, see “Starting the system”
on page 108.
3.
Verify that the amber fault LED on the replaced fan is not lit.
4.
Replace the front cover. For instructions, see “Installing the front cover on an 8335-GCA or 8335-GTA
system” on page 111.
5.
If applicable, close the rack front door.
6.
Verify the installed part. See Verifying a repair in the 8335-GCA or 8335-GTA. (www.ibm.com/
support/knowledgecenter/POWER8//p8ei3/p8ei3_verifyrepair.htm)
Removing and replacing the fan power cable in the 8335-GCA or
8335-GTA
Find information about removing and replacing the fan power cable in the IBM Power System S822LC
(8335-GCA and 8335-GTA) system.
Figure 12. Replacing a fan in the system
Removing and replacing parts
19
Содержание S822LC
Страница 1: ...Power Systems Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA IBM...
Страница 2: ......
Страница 3: ...Power Systems Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA IBM...
Страница 16: ...xiv Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA...
Страница 134: ...118 Servicing the IBM Power System S822LC 8335 GCA or 8335 GTA...
Страница 145: ...Notices 129...
Страница 146: ...IBM Printed in USA...