c.
Tighten the center load screw (B) clockwise by using the supplied hex key until a firm stop is
reached. If the heat sink moves noticeably, the load arms (A) are not engaged. Unscrew the center
load screw and repeat this step again. See Figure 97.
10.
Lightly grip the system processor module that you replaced by the edges and lift it off of the
packaging cover. Align the beveled corner of the module (A) to the corner of the packaging with
triangle (B) and place it in the packaging, as shown in Figure 98 on page 95. Close the packaging
Figure 96. Installing the heat sink
Figure 97. Tightening the center load screw on the heat sink
94
Servicing the IBM Power System S822LC (8335-GCA or 8335-GTA)