409-906-000
Nvidia::DiagnosticServiceProvider::Binomial Test Failed
Explanation:
Nvidia GPU Binomial Test Failed.
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Verify that the GPU is seated in the PCIe slot correctly by reseating the GPU. Then power cycle the system.
2.
Verify that the power connectors to the GPU are connected firmly. Then power cycle the system.
3.
Run nvidia-smi -q In some cases this will report a poorly connected power cable.
4.
Rerun the diagnostics, using the same GPU, on system that is known to be working. A variety of system issues
can cause diagnostic failure.
5.
If the problem remains, contact your IBM technical-support representative.
DSA optical drive test results
The following messages can result when you run the optical drive test.
215-000-000
Optical Drive Test Passed
Explanation:
Optical Drive Test Passed.
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
215-801-000
Optical Drive Test Aborted
Explanation:
Optical Drive Test Aborted. Unable to communicate with driver.
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1.
Make sure that the DSA Diagnostic code is at the latest level.
2.
Run the test again.
3.
Check the drive cabling for loose or broken connections at both ends or damage to the cable. Replace the cable if
damage is present.
4.
Run the test again.
5.
Check system firmware level and upgrade if necessary.The installed firmware level can be found in the DSA
Diagnostic Event Log within the Firmware/VPD section for this component.
6.
Run the test again.
409-906-000 • 215-801-000
764
IBM System x3550 M4 Type 7914: Installation and Service Guide
Содержание Redboks System x3550 M4
Страница 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 811: ...Taiwan Class A compliance statement Notices 793 ...
Страница 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 819: ......
Страница 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...