v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
Action
A newly installed hard disk
drive is not recognized.
1.
Make sure that the installed hard disk drive or ServeRAID adapter is
supported. For a list of supported optional devices, see http://www.ibm.com/
systems/info/x86servers/serverproven/compat/us/.
2.
Observe the associated yellow hard disk drive status LED. If the LED is lit, it
indicates a drive fault.
3.
If the LED is lit, remove the drive from the bay, wait 45 seconds, and reinsert
the drive, making sure that the drive assembly connects to the hard disk drive
backplane.
4.
Observe the associated green hard disk drive activity LED and the yellow
status LED:
v
If the green activity LED is flashing and the yellow status LED is not lit, the
drive is recognized by the controller and is working correctly. Run the DSA
diagnostics program to determine whether the drive is detected.
v
If the green activity LED is flashing and the yellow status LED is flashing
slowly, the drive is recognized by the controller and is rebuilding.
v
If neither LED is lit or flashing, check the hard disk drive backplane (go to
step 5).
v
If the green activity LED is flashing and the yellow status LED is lit, replace
the drive. If the activity of the LEDs remains the same, go to step 5. If the
activity of the LEDs changes, return to step 2.
5.
Make sure that the hard disk drive backplane is correctly seated. When it is
correctly seated, the drive assemblies correctly connect to the backplane
without bowing or causing movement of the backplane.
6.
Reseat the backplane power cable and repeat steps 2 through 4.
7.
Reseat the backplane signal cable and repeat steps 2 through 4.
8.
Suspect the backplane signal cable or the backplane:
v
If the server has eight hot-swap bays:
a.
Replace the affected backplane signal cable.
b.
Replace the affected backplane.
9.
See “Problem determination tips” on page 178.
Multiple hard disk drives fail.
Make sure that the hard disk drive, SAS/SATA adapter, and server device drivers
and firmware are at the latest level.
Important:
Some cluster solutions require specific code levels or coordinated code
updates. If the device is part of a cluster solution, verify that the latest level of
code is supported for the cluster solution before you update the code.
Multiple hard disk drives are
offline.
1.
Review the storage subsystem logs for indications of problems within the
storage subsystem, such as backplane or cable problems.
2.
See “Problem determination tips” on page 178.
A replacement hard disk drive
does not rebuild.
1.
Make sure that the hard disk drive is recognized by the adapter (the green
hard disk drive activity LED is flashing).
2.
Review the SAS/SATA adapter documentation to determine the correct
configuration parameters and settings.
156
IBM System x3550 M4 Type 7914: Installation and Service Guide
Содержание Redboks System x3550 M4
Страница 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 811: ...Taiwan Class A compliance statement Notices 793 ...
Страница 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 819: ......
Страница 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...