System pulse LEDs
Use this information to diagnose possible errors that are indicated by the system
pulse LEDs.
The following LEDs are on the system board and help you to monitor the system
power-on and power-off sequencing and boot progress (see “System-board LEDs”
on page 32 for the location of these LEDs).
Table 15. System pulse LEDs
LED
Description
Action
RTMM heartbeat
Power-on and power-off
sequencing.
1.
If the LED blinks at 1Hz, it is functioning
properly and no action is necessary.
2.
If the LED is not blinking, (trained
technician only) replace the system board.
IMM heartbeat
IMM2 heartbeat boot process.
The following steps describe the different
stages of the IMM2 heartbeat sequencing
process.
1.
When this LED is blinking fast
(approximately 4Hz), this indicates, that the
IMM2 code is in the loading process.
2.
When this LED goes off momentarily, this
indicates that the IMM2 code has loaded
completely.
3.
When this LED goes off momentarily and
then starts blinking slowing (approximately
1Hz), this indicates that IMM2 is fully
operational. You can now press the
power-control button to power-on the
server.
4.
If this LED does not blink within 30
seconds of connecting a power source to
the server, (trained technician only) replace
the system board.
PCI riser-card LEDs
Use this information to view PCI riser-card LEDs.
The following illustration shows the location of the PCI riser-card LEDs.
Chapter 4. Troubleshooting
145
Содержание Redboks System x3550 M4
Страница 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 811: ...Taiwan Class A compliance statement Notices 793 ...
Страница 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 819: ......
Страница 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...