3.
Reboot the system.
4.
(Trained technician only) If the error continues, replace the planar.
80070201-0301xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 1
OverTemp)
Explanation:
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702010301xxxx or 0x800702010301xxxx
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Features and specifications
for more information).
3.
Make sure that the heat sink for microprocessor n is installed correctly.
4.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
80070201-0302xxxx
Sensor [SensorElementName] has transitioned to critical from a less severe state. (CPU 2
OverTemp)
Explanation:
This message is for the use case when an implementation has detected a Sensor transitioned to critical
from less severe.
May also be shown as 800702010302xxxx or 0x800702010302xxxx
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0522
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow (front and rear of the server),
that the air baffles are in place and correctly installed, and that the server cover is installed and completely
closed.
2.
Check the ambient temperature. You must be operating within the specifications (see Features and specifications
for more information).
3.
Make sure that the heat sink for microprocessor n is installed correctly.
4.
(Trained technician only) Replace microprocessor n. (n = microprocessor number)
80070201-0301xxxx • 80070201-0302xxxx
404
IBM System x3550 M4 Type 7914: Installation and Service Guide
Содержание Redboks System x3550 M4
Страница 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 811: ...Taiwan Class A compliance statement Notices 793 ...
Страница 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 819: ......
Страница 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...