Table 14. Light path diagnostics panel LEDs (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by "(trained technician only)," that step must be performed only by a trained
technician.
LED
Description
Action
BOARD
An error has occurred on the
system board or the system
battery.
1.
Check the LEDs on the system board to identify the
component that caused the error. The BOARD LED can be
lit due to any of the following reasons:
v
Battery
v
(Trained technician only) System board
2.
Check the system-error log for information about the
error.
3.
Replace the failing component:
v
Battery (see “Removing the system battery” on page
294 and “Replacing the system battery” on page 296).
v
(Trained technician only) System board (see “Removing
the system board” on page 326 and “Replacing the
system board” on page 330).
HDD
A hard disk drive has failed or is
missing.
1.
Check the LEDs on the hard disk drives for the drive
with a lit status LED and reseat the hard disk drive.
2.
Reseat the hard disk drive backplane.
3.
For more information, see “Light path diagnostics LEDs”
on page 137.
4.
If the error remains, replace the following components
one at a time, in the order listed, restarting the server
after each:
a.
Replace the hard disk drive.
b.
Replace the hard disk drive backplane.
5.
If the problem remains, go to http://www.ibm.com/
support/entry/portal/docdisplay?lndocid=SERV-CALL.
Power-supply LEDs
Use this information to view power-supply LEDs.
The following minimum configuration is required for the server to start:
v
One microprocessor in microprocessor socket 1
v
One 2 GB DIMM on the system board
v
One power supply
v
Power cord
v
Four cooling fans (fan 1, 2, 3, and 5)
v
One PCI riser-card assembly in PCI connector 1
Chapter 4. Troubleshooting
141
Содержание Redboks System x3550 M4
Страница 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 811: ...Taiwan Class A compliance statement Notices 793 ...
Страница 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 819: ......
Страница 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...