![IBM Redboks System x3550 M4 Скачать руководство пользователя страница 559](http://html.mh-extra.com/html/ibm/redboks-system-x3550-m4/redboks-system-x3550-m4_installation-and-service-manual_608587559.webp)
806f0a0c-200cxxxx
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 12)
Explanation:
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c200cxxxx or 0x806f0a0c200cxxxx
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0146
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in
place and correctly installed, and that the server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the specifications.
3.
If a fan has failed, complete the action for a fan failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200dxxxx
An Over-Temperature Condition has been detected on the [PhysicalMemoryElementName] on
Subsystem [MemoryElementName]. (DIMM 13)
Explanation:
This message is for the use case when an implementation has detected an Over Temperature Condition
for Memory that has been Detected.
May also be shown as 806f0a0c200dxxxx or 0x806f0a0c200dxxxx
Severity:
Error
Alert Category:
Critical - Temperature
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0146
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there are no obstructions to the airflow, that the air baffles are in
place and correctly installed, and that the server cover is installed and completely closed.
2.
Make sure that ambient temperature is within the specifications.
3.
If a fan has failed, complete the action for a fan failure.
4.
Replace DIMM n. (n = DIMM number)
806f0a0c-200cxxxx • 806f0a0c-200dxxxx
Appendix A. Integrated management module II (IMM2) error messages
541
Содержание Redboks System x3550 M4
Страница 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 811: ...Taiwan Class A compliance statement Notices 793 ...
Страница 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 819: ......
Страница 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...