
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
If an action step is preceded by “(Trained technician only),” that step must be performed only by a trained
technician.
v
Go to the IBM support website at http://www.ibm.com/supportportal/ to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Symptom
Action
The OVER SPEC LED on the
light path diagnostics panel is
lit, or the Pwr rail 1 error has
been recorded in the IMM
event log.
1.
Disconnect the server power cords.
2.
(Trained technician only) remove microprocessor 1 if the Pwr rail 1 error has
been recorded in the IMM event log.
3.
(Trained technician only) replace the system board (see “Removing the system
board” on page 326 and “Replacing the system board” on page 330).
4.
Reinstall the component; then, restarting the server. If the Pwr rail 1 error has
been recorded in the IMM event log again, the component that you just
reinstalled is defective. Replace the defective component.
v
(Trained technician only) Microprocessor 1 (see “Removing a microprocessor
and heat sink” on page 310 and “Replacing a microprocessor and heat sink”
on page 315).
5.
Replace the power supply if the OVER SPEC LED on the light path diagnostics
panel is still lit.
The OVER SPEC LED on the
light path diagnostics panel is
lit, or the Pwr rail 2 error has
been recorded in the IMM
event log.
1.
Disconnect the server power cords.
2.
(Trained technician only) remove microprocessor 2 if Pwr rail 2 error has been
recorded in the IMM event log.
3.
Restart the server. If the Pwr rail 2 error has been recorded in the IMM event
log again, (trained technician only) replace the system board (see “Removing
the system board” on page 326 and “Replacing the system board” on page
330).
4.
Reinstall the component; then, restarting the server. If the Pwr Rail 2 error has
been recorded in the IMM event log again, the component that you just
reinstalled is defective. Replace the defective component.
v
(Trained technician only) Microprocessor 2 (see “Removing a microprocessor
and heat sink” on page 310 and “Replacing a microprocessor and heat sink”
on page 315).
5.
Replace the power supply if the OVER SPEC LED on the light path diagnostics
panel is still lit.
Chapter 4. Troubleshooting
167
Содержание Redboks System x3550 M4
Страница 1: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 2: ......
Страница 3: ...IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 8: ...vi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 18: ...xvi IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 42: ...24 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 118: ...100 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 214: ...196 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 352: ...334 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 702: ...684 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 798: ...780 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 802: ...784 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 811: ...Taiwan Class A compliance statement Notices 793 ...
Страница 812: ...794 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 818: ...800 IBM System x3550 M4 Type 7914 Installation and Service Guide ...
Страница 819: ......
Страница 820: ... Part Number 00Y8006 Printed in USA 1P P N 00Y8006 ...