Power Systems

Problem analysis, system parts, and

locations for the 5104-22C, 9006-12P,

9006-22C, and 9006-22P

IBM

Содержание Power Systems Series

Страница 1: ...Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P IBM...

Страница 2: ...G229 9054 and the IBM Environmental Notices and User Guide Z125 5823 This edition applies to IBM Power Systems servers that contain the POWER9 processor and to all associated models Copyright Interna...

Страница 3: ...words in system event logs 23 Identifying a service action by using sensor and event information 24 Isolation procedures 49 EPUB_PRC_FIND_DECONFIGURE_PART isolation procedure 49 EPUB_PRC_SP_CODE isola...

Страница 4: ...22P locations 91 9006 22P parts 97 Notices 109 Accessibility features for IBM Power Systems servers 110 Privacy policy considerations 111 Trademarks 111 Electronic emission notices 111 Class A Notice...

Страница 5: ...00 300 8751 German safety information Das Produkt ist nicht f r den Einsatz an Bildschirmarbeitspl tzen im Sinne 2 der Bildschirmarbeitsverordnung geeignet Laser safety information IBM servers can use...

Страница 6: ...ing unless instructed otherwise 2 For AC power remove the power cords from the outlets 3 For racks with a DC power distribution panel PDP turn off the circuit breakers located in the PDP and remove th...

Страница 7: ...devices that attach to the system It is the responsibility of the customer to ensure that the outlet is correctly wired and grounded to prevent an electrical shock R001 part 1 of 2 R001 part 2 of 2 CA...

Страница 8: ...u choose can support the weight of the loaded rack cabinet Refer to the documentation that comes with your rack cabinet for the weight of a loaded rack cabinet Verify that all door openings are at lea...

Страница 9: ...position for example when working from a ladder Stability hazard The rack may tip over causing serious personal injury Before extending the rack to the installation position read the installation ins...

Страница 10: ...e AC power cords or multiple DC power cables To remove all hazardous voltages disconnect all power cords and power cables L003 L007 CAUTION A hot surface nearby L007 x Power Systems Problem analysis s...

Страница 11: ...ing into the other end of a disconnected optical fiber to verify the continuity of optic fibers may not injure the eye this procedure is potentially dangerous Therefore verifying the continuity of opt...

Страница 12: ...preciable force so take care not to push or lean Keep riser tilt adjustable angling platform option flat at all times except for final minor angle adjustment when needed Do not stand under overhanging...

Страница 13: ...itable for connection to intrabuilding or unexposed wiring or cabling only The intrabuilding ports of this equipment must not be metallically connected to the interfaces that connect to the OSP outsid...

Страница 14: ...xiv Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...

Страница 15: ...n page 5 A system firmware boot failure occurred the system started but was not able to boot to the Petitboot menu Go to Resolving a system firmware boot failure on page 5 A video graphics array VGA m...

Страница 16: ...isplay are any sensors red If Then Yes Go to Resolving a sensor indicator problem on page 9 No Continue with the next step 7 Go to Resolving a hardware problem on page 10 This ends the procedure Resol...

Страница 17: ...hen Yes To update the BMC firmware go to Updating the system firmware by using the BMC If the problem persists go to step 12 on page 4 No Continue with the next step 6 Complete the following steps a C...

Страница 18: ...g steps a Type mkdir tmp media and press Enter b Type mount dev mapper sdb1 tmp media and press Enter c Type cd tmp media and press Enter d To update the BMC firmware type the following command and pr...

Страница 19: ...9006 22C go to 5104 22C or 9006 22C locations on page 63 to identify the physical location and the removal and replacement procedure If your system is a 9006 12P go to 9006 12P locations on page 75 to...

Страница 20: ...ressed the power button did the system turn on but fail to display the Petitboot menu If Then Yes Continue with the next step No This ends the procedure 4 Complete the following actions one at a time...

Страница 21: ...e system backplane If your system is a 5104 22C or 9006 22C go to 5104 22C or 9006 22C locations on page 63 to identify the physical location and the removal and replacement procedure If your system i...

Страница 22: ...nized and in optimal status Boot drive configuration Commands Virtual drive connected directly to the system backplane arcconf getconfig 1 LD Physical drive connected directly to the system backplane...

Страница 23: ...o to 9006 22P locations on page 91 to identify the physical location and the removal and replacement procedure a If the drive is connected directly to the system backplane ensure that the mini SAS cab...

Страница 24: ...sensor Note You must specify the SEL record ID in hexadecimal format For example 0x1a To display SEL details by using an in band network enter the following command ipmitool sel get SEL record ID To...

Страница 25: ...vice problem Learn how to access log files information to identify types of events and a list of potential problems and service actions About this task Procedure 1 To identify the correct service proc...

Страница 26: ...he PHB number PCIe bus or adapter Resolve any device driver errors that are related to I O and that occurred near the time of this operating system log entry xxx has failed 6 times in the last hour an...

Страница 27: ...of the PCIe adapter by using the slot number on page 16 Table 4 Network adapter problems and service actions Problem Service action System is unable to find the adapter or the negotiated PCIe bandwid...

Страница 28: ...ly 5 Replace the adapter 6 If the adapter is connected to a PCIe riser replace the PCIe riser 7 If the adapter is in UIO slot 1 UIO slot 2 or UIO slot 3 replace CPU 1 Otherwise replace CPU 2 8 Replace...

Страница 29: ...Other problems Check the messages and resolve any other problems that are detected Then test the NVMe Flash adapter again Resolving a storage device problem Learn about the possible problems and servi...

Страница 30: ...ved serviced or upgraded verify that the device is seated and installed properly 2 Check the system logs to verify whether the system detected a problem 3 Replace the cable that connects the disk driv...

Страница 31: ...he operating system log message nvme 0006 01 00 0 Failed status ffffffff reset controller the PCI address of the failing NVMe Flash adapter is 0006 01 00 0 b At the command line type lscfg vl pciaddre...

Страница 32: ...l elist 2 Scan the SELs for an event with the value OEM record de Did you find a SEL with the value OEM record de If Then Yes Continue with the next step No Go to step 4 on page 20 3 The OEM record de...

Страница 33: ...the most recent level of firmware that is available If this SEL event continues to be logged go to Collecting diagnostic data on page 60 Then go to Contacting IBM service and support on page 61 1Cxxx...

Страница 34: ...ort on page 61 5Exxxxxxxxxx Go to Getting fixes and update the system firmware to the most recent level of firmware that is available If this SEL event continues to be logged go to Collecting diagnost...

Страница 35: ...006 22P on page 24 This ends the procedure 9 You identified more than one event in step 5 on page 20 The service actions for all of the events that were identified in step 5 on page 20 must be perform...

Страница 36: ...regulator output If a machine check event is present with a time stamp close to the time stamp of this event search for serviceable SEL events and resolve them If a machine check event is not present...

Страница 37: ...12P 9006 22C or 9006 22P go to Identifying a service action by using sensor and event information for the 5104 22C 9006 12P 9006 22C or 9006 22P on page 24 This ends the procedure Identifying service...

Страница 38: ...service action by using sensor and event information You can use sensor and event information from the system event log SEL to determine a service action Identifying a service action by using sensor...

Страница 39: ...air flow obstructions at the front or at the rear of the system Ensure that the fans are operating properly Lower Non critical going low Lower Non critical going high Lower Critical going low Lower C...

Страница 40: ...per Critical going low Upper Critical going high Upper Non recoverable going low Upper Non recoverable going high No service action is required Backplane Fault 0x03 State Deasserted No service action...

Страница 41: ...w Lower Non critical going high Lower Critical going low Lower Critical going high Lower Non recoverable going low Lower Non recoverable going high Upper Non critical going low Upper Non critical goin...

Страница 42: ...ions at the front or at the rear of the system Ensure that the fans are operating properly Lower Non critical going low Lower Non critical going high Lower Critical going low Lower Critical going high...

Страница 43: ...procedure Thermal Trip FRB1 BIST Failure FRB2 Hang In POST Failure FRB3 Processor Startup Initialization Failure Configuration Error SMBIOS Uncorrectable CPU Complex Error Processor Disabled Terminato...

Страница 44: ...able from Less Severe Transition to Critical from Non recoverable Correctable Memory Error Parity Correctable Memory Error Logging Limit Reached Memory Automatically Throttled Critical Over temperatur...

Страница 45: ...0x1F Configuration Error Complete the following steps a If the sensor name is P1 DIMMA1 Func ensure that P1 DIMMA1 is seated properly If the sensor name is P1 DIMMA2 Func ensure that P1 DIMMA2 is seat...

Страница 46: ...wer Critical going high Lower Non recoverable going low Lower Non recoverable going high Upper Non critical going low Upper Non critical going high Upper Critical going low Upper Critical going high U...

Страница 47: ...emp 46 0x45 CPU Core Temp 47 0x46 CPU Core Temp 48 0x47 Lower Non critical going low Lower Non critical going high Lower Critical going low Lower Critical going high Lower Non recoverable going low Lo...

Страница 48: ...emove them Ensure that all of the fans are working properly by looking for serviceable events related to fans and resolving them Lower Non critical going low Lower Non critical going high Lower Critic...

Страница 49: ...going high Upper Critical going low Upper Critical going high Upper Non recoverable going low Upper Non recoverable going high No service action is required CPU1 Power 0x4E CPU2 Power 0x4F Lower Non...

Страница 50: ...tify the physical location and removal and replacement procedure FRB1 BIST Failure FRB2 Hang In POST Failure FRB3 Processor Startup Initialization Failure Configuration Error SMBIOS Uncorrectable CPU...

Страница 51: ...P locations on page 91 to identify the physical location and removal and replacement procedure FRB1 BIST Failure FRB2 Hang In POST Failure FRB3 Processor Startup Initialization Failure Configuration E...

Страница 52: ...air inlet and outlets If blockages are found remove them Ensure that all of the fans are working properly by looking for serviceable events related to fans and resolving them Performance Lags If Deas...

Страница 53: ...ch for serviceable events related to system power and voltage and resolve them Ensure all fans are working properly by looking for serviceable events related to fans and resolving them Performance Lag...

Страница 54: ...tions on page 75 or 9006 22P locations on page 91 to identify the physical location and removal and replacement procedure Lower Non critical going low Lower Non critical going high Lower Critical goin...

Страница 55: ...oing low Upper Non critical going high Upper Critical going low Upper Critical going high Upper Non recoverable going low Upper Non recoverable going high No service action required CPU Core Temp 1 0x...

Страница 56: ...p 21 0xC4 CPU Core Temp 22 0xC5 CPU Core Temp 23 0xC6 CPU Core Temp 24 0xC7 Lower Non critical going low Lower Non critical going high Lower Critical going low Lower Critical going high Lower Non reco...

Страница 57: ...ations on page 91 to identify the physical location and removal and replacement procedure FRB1 BIST Failure FRB2 Hang In POST Failure FRB3 Processor Startup Initialization Failure Configuration Error...

Страница 58: ...tify the physical location and removal and replacement procedure FRB1 BIST Failure FRB2 Hang In POST Failure FRB3 Processor Startup Initialization Failure Configuration Error SMBIOS Uncorrectable CPU...

Страница 59: ...re no air flow obstructions at the front or at the rear of the system Ensure that the fans are operating properly Lower Non critical going low Lower Non critical going high Lower Critical going low Lo...

Страница 60: ...ecoverable going low Lower Non recoverable going high Upper Non critical going low Upper Non critical going high Upper Critical going low Upper Critical going high Upper Non recoverable going low Uppe...

Страница 61: ...9006 22P locations on page 91 to identify the physical location and removal and replacement procedure Lower Non critical going low Lower Non critical going high Lower Critical going low Lower Critica...

Страница 62: ...tem occurred No service action is required If there is no deassert event immediately following the assert event replace the power supply If the sensor name is PS1 Status replace PSU 1 If the sensor na...

Страница 63: ...to examine system event logs SELs To list SELs by using an in band network use the following command ipmitool sel elist To list SELs remotely over the LAN use the following command ipmitool I lanplus...

Страница 64: ...tected in the system firmware About this task Update the system firmware image Go to Getting fixes and update the system firmware with the most recent level of firmware Then reboot the system If the s...

Страница 65: ...val and replacement procedure If the replacement of the system processors and the system backplane does not resolve the problem go to Contacting IBM service and support on page 61 This ends the proced...

Страница 66: ...replacement procedure If your system is a 9006 22P go to 9006 22P locations on page 91 to identify the physical location and the removal and replacement procedure If the sensor name is Membuf Func x r...

Страница 67: ...on page 75 to identify the physical location and removal and replacement procedure If the replacement of the system processors and the system backplane does not resolve the problem go to Contacting IB...

Страница 68: ...on page 75 to identify the physical location and removal and replacement procedure If replacing the system backplane and both system processors does not resolve the problem go to Contacting IBM servi...

Страница 69: ...dentify the physical location and removal and replacement procedure If replacing the system backplane and both system processors does not resolve the problem go to Contacting IBM service and support o...

Страница 70: ...CPU Func 1 or CPU Core Func x where x is 1 12 replace system processor CPU 1 If the sensor name is CPU Func 2 or CPU Core Func x where x is 13 24 replace system processor CPU 2 Does the problem persis...

Страница 71: ...tem processor CPU 1 If replacing the system processor CPU 1 does not resolve the problem replace system processor CPU 2 Go to 9006 22P locations on page 91 to identify the physical location and remova...

Страница 72: ...nc x where x is 1 12 replace system processor CPU 1 If the sensor name is CPU Func 2 or CPU Core Func x where x is 13 24 replace system processor CPU 2 Does the problem persist If Then Yes Replace the...

Страница 73: ...replacement procedure If replacing the system backplane and both system processors does not resolve the problem go to Contacting IBM service and support on page 61 This ends the procedure EPUB_PRC_CO...

Страница 74: ...e following table to determine the verification action to complete Table 17 Determining a verification action for PCIe adapters and devices Adapter type Verification action Devices that are not contro...

Страница 75: ...collected during this procedure to IBM service and support This ends the procedure Contacting IBM service and support You can contact IBM service and support by telephone or through the IBM Support Po...

Страница 76: ...ing system problem IBM application program Loop hang or message Hardware IBM system hardware broken Hardware reference code IBM input output I O problem Upgrade 1 800 IBM SERV 1 800 426 7378 62 Power...

Страница 77: ...the following tables Figure 1 Front view Table 19 Front view locations Index number FRU description FRU removal and replacement procedures 1 HDD 0 See Removing and replacing a disk drive in the 5104...

Страница 78: ...or 9006 22C 9 HDD 8 See Removing and replacing a disk drive in the 5104 22C or 9006 22C 10 HDD 9 See Removing and replacing a disk drive in the 5104 22C or 9006 22C 11 HDD 10 See Removing and replacin...

Страница 79: ...replacing fans in the 5104 22C or 9006 22C 18 CPU 1 See Removing and replacing a system processor module for the 5104 22C or 9006 22C 19 CPU 2 See Removing and replacing a system processor module for...

Страница 80: ...CIe adapters in the 9006 22C 29 PCIe adapter 4 WIO R Slot See Removing and replacing PCIe adapters in the 9006 22C 30 PCIe adapter 5 WIO Slot2 See Removing and replacing PCIe adapters in the 5104 22C...

Страница 81: ...104 22C or 9006 22C 35 P1 DIMMA2 See Removing and replacing memory in the 5104 22C or 9006 22C 36 P1 DIMMB1 See Removing and replacing memory in the 5104 22C or 9006 22C 37 P1 DIMMB2 See Removing and...

Страница 82: ...006 22C 46 P2 DIMMC1 See Removing and replacing memory in the 5104 22C or 9006 22C 47 P2 DIMMC2 See Removing and replacing memory in the 5104 22C or 9006 22C 48 P2 DIMMD1 See Removing and replacing me...

Страница 83: ...IBM part number Supermicro part number Units per assembly Description 1 01EM628 MCP 290 0 0057 0N 1 Slide rail kit contains left and right slide rails and attaching screws 2 01EM628 MCP 290 0 0057 0N...

Страница 84: ...System parts Figure 6 System parts 70 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...

Страница 85: ...ible with system processor modules with version DD2 01 01EM360 PP9 MP02AA798 K IB001 1 2 16 core 2 7 GHz DD2 01system processor module kit includes system processor module tray and removal tool 9006 2...

Страница 86: ...the 5104 22C or 9006 22C 16 01EM721 AOC 2UR688 i4XTF IB001 1 2U UIO NIC PCIe adapter with integrated 4 port 10 GbE Base T Intel XL710 and CAPI Note This PCIe adapter is also a PCIe riser 17 1 PCIe ca...

Страница 87: ...ro part number Units per assembly 50 cm OCuLink OCuLink X8 cable 01EM626 CBL SAST 0934 12 Slide rail kit for round hole racks contains left and right slide rails and attaching screws 5104 22C 01EM630...

Страница 88: ...74 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...

Страница 89: ...d replaceable unit FRU layouts in the system Use these diagrams with the following tables Figure 7 Front view Table 26 Front view locations Index number FRU description FRU removal and replacement pro...

Страница 90: ...nd replacing fans in the 9006 12P 8 Fan 3 See Removing and replacing fans in the 9006 12P 9 Fan 4 See Removing and replacing fans in the 9006 12P 10 Fan 5 See Removing and replacing fans in the 9006 1...

Страница 91: ...ted platform module TPM card See Removing and replacing the TPM card in the 9006 12P Figure 9 Rear view Table 28 Rear view locations Index number FRU description FRU removal and replacement procedures...

Страница 92: ...following table Figure 10 Memory locations The following table provides the memory locations Table 29 Memory locations Index number FRU description FRU removal and replacement procedures 26 P1 DIMMA1...

Страница 93: ...g and replacing memory in the 9006 12P 36 P2 DIMMB1 See Removing and replacing memory in the 9006 12P 37 P2 DIMMB2 See Removing and replacing memory in the 9006 12P 38 P2 DIMMC1 See Removing and repla...

Страница 94: ...on module DOM 2 See Removing and replacing a storage drive in the 9006 12P 9006 12P parts Use this information to find the field replaceable unit FRU part number After you identify the part number of...

Страница 95: ...IBM part number Supermicro part number Units per assembly Description 1 02CM137 MCP 290 0 0052 0N 1 Slide rail kit contains left and right slide rails and attaching screws 2 02CM137 MCP 290 0 0052 0N...

Страница 96: ...or the 9006 12P 3 01EM611 RSC W 66P IB001 1 PCIe riser for PCIe adapters Use the feature type of the adapter to find the FRU number in PCIe adapter information by feature type for the 9006 12P 4 1 PCI...

Страница 97: ...feature type of the adapter to find the FRU number in PCIe adapter information by feature type for the 9006 12P 8 01EM608 AOC UR i4XTF IB001 1 1U UIO NIC PCIe adapter with integrated 4 port 10 GbE Ba...

Страница 98: ...A10T ST10000NM0096 4 10 0 TB 7 2K 512 block size 3 5 inch SAS disk drive 01EM656 HDD A4000 ST4000NM0075 4 4 0 TB 7 2K 4k block size 3 5 inch self encrypting SAS disk drive 01EM657 HDD A8000 ST8000NM00...

Страница 99: ...elf encrypting SAS solid state drive 1 drive write per day 01EM676 HDS KIT 2A 3840S IB001 4 3 84 TB 2 5 inch self encrypting SAS solid state drive 1 drive write per day 01EM664 HDS KIT 2T 240 IB001 4...

Страница 100: ...Me solid state drive 0 8 drive writes per day 01EM681 HDS KIT 08N 3840 IB001 4 3 84 TB 2 5 inch NVMe solid state drive 0 8 drive writes per day 01EM668 HDS KIT 5N 800 IB001 4 800 GB 2 5 inch NVMe soli...

Страница 101: ...Additional system parts Figure 14 Additional system parts Finding parts and locations 87...

Страница 102: ...66 MHz 2RX4 DDR4 IS RDIMM 01EM647 MEM DR464L CL01 ER26 for Micron Technology Inc or MEM DR464L SL01 ER26 for Samsung Electronics Co Ltd 16 64 GB 2666 MHz 4RX4 DDR4 IS RDIMM 01EM648 MEM DR412L CL01 ER2...

Страница 103: ...of the memory in a 9006 12P system must be the same size The 9006 12P system does not support mixing different sizes of memory 9006 12P systems do not support mixing system processors with different s...

Страница 104: ...umber Supermicro part number Rail adapter bracket kit contains 4 brackets to adapt to round holes 02CM145 MCP 290 81904 0 N CR2032 Lithium time of day battery 90 Power Systems Problem analysis system...

Страница 105: ...ont view Table 35 Front view locations Index number FRU description FRU removal and replacement procedures 1 HDD 0 See Removing and replacing a disk drive in the 9006 22P 2 HDD 1 See Removing and repl...

Страница 106: ...3 See Removing and replacing a disk drive in the 9006 22P For more information about the placement of HDD and NVMe FRUs see Drive installation information for the 9006 22P system Figure 16 Top view T...

Страница 107: ...the 9006 22P 19 CPU 2 See Removing and replacing a system processor module for the 9006 22P 20 Time of day battery See Removing and replacing the time of day battery in the 9006 22P 21 System backplan...

Страница 108: ...in the 9006 22P 28 PCIe adapter 3 WIO Slot1 See Removing and replacing PCIe adapters in the 9006 22P 29 PCIe adapter 4 WIO R Slot See Removing and replacing PCIe adapters in the 9006 22P 30 PCIe adap...

Страница 109: ...moving and replacing memory in the 9006 22P 36 P1 DIMMB1 See Removing and replacing memory in the 9006 22P 37 P1 DIMMB2 See Removing and replacing memory in the 9006 22P 38 P1 DIMMC1 See Removing and...

Страница 110: ...46 P2 DIMMC1 See Removing and replacing memory in the 9006 22P 47 P2 DIMMC2 See Removing and replacing memory in the 9006 22P 48 P2 DIMMD1 See Removing and replacing memory in the 9006 22P 49 P2 DIMMD...

Страница 111: ...g a disk drive in the 9006 22P 51 Drive on module DOM 2 See Removing and replacing a disk drive in the 9006 22P 9006 22P parts Use this information to find the field replaceable unit FRU part number A...

Страница 112: ...Units per assembly Description 1 01EM628 MCP 290 0 0057 0N 1 Slide rail kit contains left and right slide rails and attaching screws 2 01EM628 MCP 290 0 0057 0N 1 Slide rail kit contains left and righ...

Страница 113: ...r IBM part number Supermicro part number Units per assembly Description 1 1 Top cover assembly 2 Screws 2 1 PCI adapter Use the feature type of the adapter to find the FRU number in PCIe adapter infor...

Страница 114: ...ly rear drive backplane two rear drive trays two rear drive fillers two disk drive signal cables drive power cable 8 pin female connector to one right angle 4 pin female connector and signal cable 8 p...

Страница 115: ...Additional system parts Figure 23 Additional system parts Finding parts and locations 101...

Страница 116: ...gy Inc or MEM DR416L SL02 ER26 for Samsung Electronics Co Ltd 16 16 GB 2666 MHz 1RX4 DDR4 IS RDIMM 01EM646 MEM DR432L CL01 ER26 for Micron Technology Inc or MEM DR432L SL02 ER26 for Samsung Electronic...

Страница 117: ...re 2 7 GHz DD2 21 system processor module kit includes system processor module tray and removal tool 01EM478 PP9 MP02CY087 K IB001 1 2 22 core 2 6 GHz DD2 2 system processor module kit includes system...

Страница 118: ...55 HDD A10T ST10000NM0096 12 10 0 TB 7 2K 512 block size 3 5 inch SAS disk drive 01EM656 HDD A4000 ST4000NM0075 12 4 0 TB 7 2K 4k block size 3 5 inch self encrypting SAS disk drive 01EM657 HDD A8000 S...

Страница 119: ...h self encrypting SAS solid state drive 1 drive write per day 01EM676 HDS KIT 2A 3840S IB001 12 14 3 84 TB 2 5 inch self encrypting SAS solid state drive 1 drive write per day 01EM664 HDS KIT 2T 240 I...

Страница 120: ...6 TB 2 5 inch NVMe solid state drive 5 drive writes per day 01EM670 HDS KIT 5N 3200 IB001 12 3 2 TB 2 5 inch NVMe solid state drive 5 drive writes per day 23 01EM619 PWS 1K22A 1R 1 1200 W power supply...

Страница 121: ...ve backplane power cable 8 pin female connector to two 4 pin female connectors 02CM141 CBL PWEX 0673 50 cm OCuLink OCuLink X8 cable 01EM626 CBL SAST 0934 12 Disk drive backplane signal cable mini SAS...

Страница 122: ...108 Power Systems Problem analysis system parts and locations for the 5104 22C 9006 12P 9006 22C and 9006 22P...

Страница 123: ...ct s and or the program s described in this publication at any time without notice Any references in this information to non IBM websites are provided for convenience only and do not in any manner ser...

Страница 124: ...content successfully Overview The IBM Power Systems servers include the following major accessibility features Keyboard only operation Operations that use a screen reader The IBM Power Systems servers...

Страница 125: ...tware Offering does not use cookies or other technologies to collect personally identifiable information If the configurations deployed for this Software Offering provide you as the customer the abili...

Страница 126: ...his device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference r...

Страница 127: ...t explains the JEITA statement for products greater than 20 A single phase This statement explains the JEITA statement for products greater than 20 A per phase three phase Electromagnetic Interference...

Страница 128: ...Warnhinweis versehen werden Warnung Dieses ist eine Einrichtung der Klasse A Diese Einrichtung kann im Wohnbereich Funk St rungen verursachen in diesem Fall kann vom Betreiber verlangt werden angemess...

Страница 129: ...ment into an outlet on a circuit different from that to which the receiver is connected Consult an IBM authorized dealer or service representative for help Properly shielded and grounded cables and co...

Страница 130: ...plains the Japan Electronics and Information Technology Industries Association JEITA statement for products less than or equal to 20 A per phase This statement explains the JEITA statement for product...

Страница 131: ...epublik Deutschland Zulassungsbescheinigung laut dem Deutschen Gesetz ber die elektromagnetische Vertr glichkeit von Ger ten EMVG bzw der EMC Richtlinie 2014 30 EU f r Ger te der Klasse B Dieses Ger t...

Страница 132: ...es the right to withdraw the permissions granted herein whenever in its discretion the use of the publications is detrimental to its interest or as determined by IBM the above instructions are not bei...

Страница 133: ......

Страница 134: ...IBM...