25.
Perform all the following steps for each entry in the list of all partitions you recorded in step 11 on
page 194, except for the partition you were using to debug the original problem.
26.
From the list of all partitions, open the IVM virtual terminal window of a partition, and then type
diag
at the AIX command prompt.
27.
When the diagnostic operating instructions are displayed, complete the following steps:
1.
Press Enter.
2.
Select the
Task Selection
option.
3.
Select the
Log Repair
option.
4.
Select the resource associated with the repair action:
v
If the repair action was reseating a cable or adapter, select the resource associated with that repair action.
v
If the resource associated with your repair action is not displayed on the Resource List, select
sysplanar0
.
5.
Click
Commit
after you make your selection.
Note:
If the terminal type is not defined, you are prompted to define it before you can proceed.
28.
Exit from diagnostics in this partition and return to the AIX command prompt.
29.
Have all the partitions in the list of all partitions you recorded in step 11 on page 194 been
processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 25 to process the next partition in the list you recorded in step 11 on page 194.
30.
Have all the serviceable events recorded in step 4 on page 193 been processed?
v
Yes:
Continue with the next step.
v
No:
Go to step 5 on page 194 and process the next service action event in the list of serviceable events recorded in
step 4 on page 193.
31.
While processing all service action events, were you directed to step 14 on page 195?
v
Yes:
Continue with the next step.
v
No:
If the system attention LED is still on, turn off the LED as described in “Activating and deactivating LEDs” on
page 197. Return the system to the customer.
This completes the repair.
Note:
If during the processing of the list of open service action events, some service action events remained open,
further service actions might be required to complete the repair.
32.
Complete all the following steps for each entry in the list of A
xx
partitions you began recording in
step 14 on page 195, except for the partition you were using to debug the original problem.
33.
From the list of A
xx
partitions, open the management console virtual terminal window of a partition
, and then type
diag
at the AIX command prompt.